Pepperl+Fuchs NCB10-30GM40-N0-15M-OG
Inductive sensor

Pepperl+Fuchs NCB10-30GM40-N0-15M-OG
We ship to United States of America!
  • 10 mm flush
  • Shielded PUR cable for oil and gas sector
Item Number: NCB10-30GM40-N0-15M-OG
200.49
-
+
Total price: 200.49
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +
Reverse polarity protectionreverse polarity protected
Effective internal capacitancemax. 105 nF
A cable length of 10 m is considered.
Switching frequency0 ... 650 Hz
Switching state indicatorLED, yellow
CE marking[*PD-Z02586A*]
Effective internal inductancemax. 100 andmicro;H
A cable length of 10 m is considered.
MTTFd1870 a
Connection typecable PUR (halogen-free) , 15 m , screened , Oil resistant , Flame-retardant as per IEC 60332-1
Switching functionNormally closed (NC)
Storage temperature-40 ... 80 ?°C (-40 ... 176 ?°F)
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
Degree of protectionIP66 / IP67
Effective internal inductancemax. 100 andmicro;H
A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 ?°C (212 ?°F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 ?°C (212 ?°F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 81 ?°C (177.8 ?°F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 63 ?°C (145.4 ?°F)
Type of protectionintrinsic safety
Short-circuit protectionyes
Effective internal capacitancemax. 105 nF
A cable length of 10 m is considered.
Reduction factor rAl 0.32
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Output typeNAMUR
Output type3-wire
Type of protectionintrinsic safety
Reduction factor rCu 0.32
Type of protectionintrinsic safety
Effective internal capacitancemax. 105 nF
A cable length of 10 m is considered.
Equipment protection levelGa , Gb , Gc (ic) , Da , Mb
Nominal voltage8 V
Type of protectionintrinsic safety
Use in the hazardous areasee instruction manuals
CCC approvalCCC approval / marking not required for products rated 36 V
Core cross-section2x 0.5 mm2
Rated operating distance10 mm
Sensing facePBT
Housing materialStainless steel 1.4305 / AISI 303
CE marking[*PD-Z02585A*]
NoteThe shield is not connected to the sensor.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 ?°C (212 ?°F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 ?°C (212 ?°F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 81 ?°C (177.8 ?°F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 63 ?°C (145.4 ?°F)
Effective internal inductancemax. 100 andmicro;H
A cable length of 10 m is considered.
CE marking[*PD-Z02585A*]
Effective internal capacitancemax. 105 nF
A cable length of 10 m is considered.
Diagnostic Coverage (DC)0 %
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 20 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 55 ?°C (131 ?°F)
T5 : 55 ?°C (131 ?°F)
T4 : 55 ?°C (131 ?°F)
T3 : 55 ?°C (131 ?°F)
T2 : 55 ?°C (131 ?°F)
T1 : 55 ?°C (131 ?°F)
at Ui = 20 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 55 ?°C (131 ?°F)
T5 : 55 ?°C (131 ?°F)
T4 : 55 ?°C (131 ?°F)
T3 : 55 ?°C (131 ?°F)
T2 : 55 ?°C (131 ?°F)
T1 : 55 ?°C (131 ?°F)
at Ui = 20 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 52 ?°C (125.6 ?°F)
T5 : 52 ?°C (125.6 ?°F)
T4 : 52 ?°C (125.6 ?°F)
T3 : 52 ?°C (125.6 ?°F)
T2 : 52 ?°C (125.6 ?°F)
T1 : 52 ?°C (125.6 ?°F)
at Ui = 20 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 44 ?°C (111.2 ?°F)
T5 : 44 ?°C (111.2 ?°F)
T4 : 44 ?°C (111.2 ?°F)
T3 : 44 ?°C (111.2 ?°F)
T2 : 44 ?°C (111.2 ?°F)
T1 : 44 ?°C (111.2 ?°F)
CE marking[*PD-Z02585A*]
Reduction factor r304 0.72
Effective internal inductancemax. 100 andmicro;H
A cable length of 10 m is considered.
Ambient temperature-25 ... 80 ?°C (-13 ... 176 ?°F)
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 76 ?°C (168.8 ?°F)
T5 : 91 ?°C (195.8 ?°F)
T4 : 100 ?°C (212 ?°F)
T3 : 100 ?°C (212 ?°F)
T2 : 100 ?°C (212 ?°F)
T1 : 100 ?°C (212 ?°F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 73 ?°C (163.4 ?°F)
T5 : 88 ?°C (190.4 ?°F)
T4 : 100 ?°C (212 ?°F)
T3 : 100 ?°C (212 ?°F)
T2 : 100 ?°C (212 ?°F)
T1 : 100 ?°C (212 ?°F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 62 ?°C (143.6 ?°F)
T5 : 77 ?°C (170.6 ?°F)
T4 : 81 ?°C (177.8 ?°F)
T3 : 81 ?°C (177.8 ?°F)
T2 : 81 ?°C (177.8 ?°F)
T1 : 81 ?°C (177.8 ?°F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 54 ?°C (129.2 ?°F)
T5 : 63 ?°C (145.4 ?°F)
T4 : 63 ?°C (145.4 ?°F)
T3 : 63 ?°C (145.4 ?°F)
T2 : 63 ?°C (145.4 ?°F)
T1 : 63 ?°C (145.4 ?°F)
Type of protectionintrinsic safety
CSA approvalcCSAus Listed, General Purpose
Mission Time (TM)20 a
Installationflush
Assured operating distance0 ... 8.1 mm
UL approvalcULus Listed, General Purpose
Effective internal capacitancemax. 105 nF
A cable length of 10 m is considered.
Actual operating distance9 ... 11 mm typ.
Effective internal inductancemax. 100 andmicro;H
A cable length of 10 m is considered.
Hysteresis1 ... 10 typ. 5 %

Buy Pepperl+Fuchs NCB10-30GM40-N0-15M-OG with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services and exceptional support.

Comments

No comments yet

Write a comment