Pepperl+Fuchs NCB2-12GM40-E2-5M-3G-3D
Inductive sensor
- Comfort series
- ATEX-approval for zone 2 and zone 22
Item Number:
NCB2-12GM40-E2-5M-3G-3D
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
MTTFd | 1507 a |
Output type | PNP |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 В°C (109.4 В°F) at UBmax = 30 V , IL = 100 mA : 50 В°C (122 В°F) at UBmax = 30 V , IL = 50 mA : 53 В°C (127.4 В°F) |
Degree of protection | IP67 |
Type of protection | Protection by enclosure ""tc"" |
Output type | 3-wire |
Reduction factor r304 | 0.67 |
Short-circuit protection | pulsing |
CCC approval | CCC approval / marking not required for products rated 36 V |
Operating current | 200 mA |
Mission Time (TM) | 20 a |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax |
Output polarity | DC |
Type of protection | ""n"" |
Reduction factor rAl | 0.3 |
Actual operating distance | 1.8 ... 2.2 mm typ. 2 mm |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 В°C (109.4 В°F) at UBmax = 30 V , IL = 100 mA : 50 В°C (122 В°F) at UBmax = 30 V , IL = 50 mA : 53 В°C (127.4 В°F) |
Rated operating distance | 2 mm |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Voltage drop | 3 V |
Connection type | cable PVC , 5 m |
No-load supply current | 15 mA |
Diagnostic Coverage (DC) | 0 % |
Reverse polarity protection | reverse polarity protected |
Core cross-section | 0.34 mm2 |
Switching frequency | 0 ... 2500 Hz |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Installation | flush |
CE marking | [*PD-Z02586A*] |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA |
Hysteresis | 3 ... 15 typ. 6 % |
Sensing face | PBT |
Surge protection | The protection against transient overvoltage with amplitude U is realized. U = 500 V at 1.2/50 micro/s, 500 andOmega; |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Scope of delivery | 2 self locking nuts in scope of delivery |
CE marking | [*PD-Z02586A*] |
Time delay before availability | 100 ms |
Switching function | Normally open (NO) |
Reduction factor rBrass | 0.35 |
Switching state indicator | LED, yellow |
Housing material | Stainless steel 1.4305 / AISI 303 |
Equipment protection level | Gc (nA) , Dc |
Assured operating distance | 0 ... 1.62 mm |
Use in the hazardous area | see instruction manuals |
Operating voltage | 10 ... 30 V DC |
Reduction factor rCu | 0.17 |