Pepperl+Fuchs NCB8-18GM40-N0-10M-OG
Inductive sensor
- 8 mm flush
- Usable up to SIL 2 acc. to IEC 61508
- Overview
- Comments
Housing material | Stainless steel 1.4305 / AISI 303 |
Mission Time (TM) | 20 a |
Installation | flush |
Reduction factor rAl | 0.39 |
Diagnostic Coverage (DC) | 0 % |
Assured operating distance | 0 ... 6.48 mm |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Connection type | cable PUR (halogen-free) , 10 m blue , Oil resistant , Flame-retardant as per IEC 60332-1 Mud-resistant according to IEC61892-4, appendix D Flexible at temperatures as low as -40 В°C |
Use in the hazardous area | see instruction manuals |
Reduction factor r304 | 0.71 |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
Short-circuit protection | yes |
Ambient temperature | -25 ... 80 В°C (-13 ... 176 В°F) |
Degree of protection | IP66 / IP67 |
Actual operating distance | 7.2 ... 8.8 mm typ. 8 mm |
Rated operating distance | 8 mm |
Core cross-section | 2x 1 mm2 , black |
Switching frequency | 0 ... 1500 Hz |
Output type | NAMUR |
Reduction factor rCu | 0.36 |
Storage temperature | -40 ... 80 В°C (-40 ... 176 В°F) |
Switching state indicator | all direction LED, yellow |
Hysteresis | 1 ... 15 typ. 5 % |
MTTFd | 2660 a |
Switching function | Normally closed (NC) |
Reverse polarity protection | reverse polarity protected |
Sensing face | PBT |
Output type | 2-wire |
People also buy
Comments
No comments yet