Pepperl+Fuchs NCN15-30GM40-N0-30M
Inductive sensor

Pepperl+Fuchs NCN15-30GM40-N0-30M
  • Comfort series
  • Stainless steel housing
Item Number: NCN15-30GM40-N0-30M
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Reduction factor r304 0.7
Degree of protectionIP67
CE marking[*PD-Z02585A*]
CE marking[*PD-Z02585A*]
Effective internal inductancemax. 100 andmicro;H ; a cable length of 10 m is considered.
Hysteresis5 ... 15 typ. 5 %
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Housing materialStainless steel 1.4305 / AISI 303
Standard conformityEN 60079-15:2005 Ignition protection category ""n""
Use is restricted to the following stated conditions
Connection typecable PVC , 30 m
Switching frequency0 ... 150 Hz
ATEX marking II 3D Ex tc IIIC T80В°C Dc
The Ex-related marking can also be printed on the enclosed label.
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Use in the hazardous areasee instruction manuals
Appropriate typeNCN15-30GM...-N0...
Assured operating distance0 ... 12.15 mm
Core cross-section0.75 mm2
Output type2-wire
Installationnon-flush
Storage temperature-40 ... 100 В°C (-40 ... 212 В°F)
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga
The Ex-significant identification is on the enclosed adhesive label
Sensing facePBT
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ""ic"" Use is restricted to the following stated conditions
Actual operating distance13.5 ... 16.5 mm typ.
Switching state indicatorall direction LED, yellow
Effective internal capacitancemax. 110 nF ; a cable length of 10 m is considered.
Nominal voltage8 V DC
Effective internal inductancemax. 100 andmicro;H ; a cable length of 10 m is considered.
CCC approvalCCC approval / marking not required for products rated 36 V
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
ATEX marking II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label.
EAC conformityTR CU 012/2011
Effective internal inductancemax. 100 andmicro;H ; A cable length of 10 m is considered.
Switching functionNormally closed (NC)
Effective internal capacitance Cimax. 110 nF ; A cable length of 10 m is considered.
Maximum permissible ambient temperature
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
Reduction factor rCu 0.35
Effective internal capacitancemax. 110 nF ; a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
CE marking[*PD-Z02585A*]
Reduction factor rAl 0.4
Appropriate typeNCN15-30GM...-N0...
Rated operating distance15 mm
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure ""tc"" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
CE marking[*PD-Z02585A*]
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
CSA approvalcCSAus Listed, General Purpose
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-related marking can also be printed on the enclosed label.
CertificatePF 13 CERT 2895 X
Effective internal inductance Limax. 100 andmicro;H ; A cable length of 10 m is considered.
Effective internal capacitancemax. 110 nF ; a cable length of 10 m is considered.
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
UL approvalcULus Listed, General Purpose
ATEX marking II 3G Ex ic IIC T6andhellip;T1 Gc
The Ex-significant identification is on the enclosed adhesive label
Effective internal inductancemax. 100 andmicro;H ; a cable length of 10 m is considered.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Appropriate typeNCN15-30GM...-N0...
CE marking[*PD-Z02586A*]
Output typeNAMUR
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Effective internal capacitancemax. 110 nF ; a cable length of 10 m is considered.

Comments

No comments yet

Write a comment