Reduction factor r304 | 0.7 |
Degree of protection | IP67 |
CE marking | [*PD-Z02585A*] |
CE marking | [*PD-Z02585A*] |
Effective internal inductance | max. 100 andmicro;H ; a cable length of 10 m is considered. |
Hysteresis | 5 ... 15 typ. 5 % |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Housing material | Stainless steel 1.4305 / AISI 303 |
Standard conformity | EN 60079-15:2005 Ignition protection category ""n"" Use is restricted to the following stated conditions |
Connection type | cable PVC , 30 m |
Switching frequency | 0 ... 150 Hz |
ATEX marking | II 3D Ex tc IIIC T80В°C Dc The Ex-related marking can also be printed on the enclosed label. |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Use in the hazardous area | see instruction manuals |
Appropriate type | NCN15-30GM...-N0... |
Assured operating distance | 0 ... 12.15 mm |
Core cross-section | 0.75 mm2 |
Output type | 2-wire |
Installation | non-flush |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
ATEX marking | II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-significant identification is on the enclosed adhesive label |
Sensing face | PBT |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ""ic"" Use is restricted to the following stated conditions |
Actual operating distance | 13.5 ... 16.5 mm typ. |
Switching state indicator | all direction LED, yellow |
Effective internal capacitance | max. 110 nF ; a cable length of 10 m is considered. |
Nominal voltage | 8 V DC |
Effective internal inductance | max. 100 andmicro;H ; a cable length of 10 m is considered. |
CCC approval | CCC approval / marking not required for products rated 36 V |
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
EAC conformity | TR CU 012/2011 |
Effective internal inductance | max. 100 andmicro;H ; A cable length of 10 m is considered. |
Switching function | Normally closed (NC) |
Effective internal capacitance Ci | max. 110 nF ; A cable length of 10 m is considered. |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
Reduction factor rCu | 0.35 |
Effective internal capacitance | max. 110 nF ; a cable length of 10 m is considered. |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. |
CE marking | [*PD-Z02585A*] |
Reduction factor rAl | 0.4 |
Appropriate type | NCN15-30GM...-N0... |
Rated operating distance | 15 mm |
Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure ""tc"" Some of the information in this instruction manual is more specific than the information provided in the datasheet. |
CE marking | [*PD-Z02585A*] |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | yes |
CSA approval | cCSAus Listed, General Purpose |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
ATEX marking | II 1G Ex ia IIC T6andhellip;T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Certificate | PF 13 CERT 2895 X |
Effective internal inductance Li | max. 100 andmicro;H ; A cable length of 10 m is considered. |
Effective internal capacitance | max. 110 nF ; a cable length of 10 m is considered. |
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! The ATEX Directive applies only to the use of apparatus under atmospheric conditions. If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced. |
UL approval | cULus Listed, General Purpose |
ATEX marking | II 3G Ex ic IIC T6andhellip;T1 Gc The Ex-significant identification is on the enclosed adhesive label |
Effective internal inductance | max. 100 andmicro;H ; a cable length of 10 m is considered. |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Appropriate type | NCN15-30GM...-N0... |
CE marking | [*PD-Z02586A*] |
Output type | NAMUR |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Effective internal capacitance | max. 110 nF ; a cable length of 10 m is considered. |