Pepperl+Fuchs NCN3-F25F-N4-Y41364
Inductive sensor
We ship to United States of America!
- For installation in housing
- Direct mounting on standard actuators
- ATEX IECEX certifications
Item Number:
NCN3-F25F-N4-Y41364
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Installation | flush mountable |
Assured operating distance | 0 ... 2.43 mm |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Nominal voltage | 8.2 V (Ri approx. 1 kandOmega;) |
Reduction factor r304 | 0.86 |
Output type | 2-wire |
Reduction factor rCu | 0.43 |
Reduction factor rBrass | 0.54 |
Use in the hazardous area | see instruction manuals |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Type of protection | intrinsic safety |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Connection type | MINI-COMBICON |
Tightening torque, fastening screws | M5 x 25 : 2.7 Nm |
Housing material | PBT |
Type of protection | intrinsic safety |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Effective internal inductance | max. 100 andmicro;H A cable length of 10 m is considered. |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Type of protection | intrinsic safety |
Reduction factor rAl | 0.52 |
CSA approval | cCSAus Listed, General Purpose |
Type of protection | intrinsic safety |
Diagnostic Coverage (DC) | 0 % |
Short-circuit protection | yes |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Type of protection | intrinsic safety |
Switching frequency | 0 ... 1500 Hz |
Output type | NAMUR |
Hysteresis | typ. 5 % |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
CE marking | [*PD-Z02585A*] |
Mass | 37 g |
Time delay before availability | 1 ms |
CE marking | [*PD-Z02585A*] |
Equipment protection level | Ga , Gb , Gc (ic) , Da , Mb |
Actual operating distance | 2.7 ... 3.3 mm typ. |
Mission Time (TM) | 20 a |
Reverse polarity protection | reverse polarity protected |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Switching state indicator | LED, yellow |
Sensing face | PBT |
Note | Please use Phönix FK-MCP 1,5/4-ST-3,81 connector |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 95 В°C (203 В°F) |
Reduction factor rSt37 | 1 |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 В°C (167 В°F) T5 : 90 В°C (194 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 В°C (140 В°F) T5 : 75 В°C (167 В°F) T4 : 95 В°C (203 В°F) T3 : 95 В°C (203 В°F) T2 : 95 В°C (203 В°F) T1 : 95 В°C (203 В°F) |
UL approval | cULus Listed, General Purpose |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Rated operating distance | 3 mm |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
MTTFd | 1038 a |
Switching function | 2 x normally closed (NC) |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 95 В°C (203 В°F) |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 В°C (167 В°F) T5 : 90 В°C (194 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 В°C (140 В°F) T5 : 75 В°C (167 В°F) T4 : 95 В°C (203 В°F) T3 : 95 В°C (203 В°F) T2 : 95 В°C (203 В°F) T1 : 95 В°C (203 В°F) |
Degree of protection | IP67 (Sensor side) IP20 (Connection side) |
Buy Pepperl+Fuchs NCN3-F25F-N4-Y41364 with the best possible price and delivery terms on eltra-trade.com
Find the industrial control components you need at eltra-trade.com. Our catalog offers a variety of sizes and types, all available for prompt delivery. Enjoy competitive pricing and excellent customer service. Trust us to fulfill your automation equipment requirements efficiently and reliably.
People also buy
Comments
No comments yet