Pepperl+Fuchs NCN3-F31-N4-V1-Y223958 Inductive sensor


Item Number: NCN3-F31-N4-V1-Y223958
- Direct mounting on standard actuators
- Fixed setting
- EC-Type Examination Certificate TГњV99 ATEX 1479X
- Usable up to SIL 2 acc. to IEC 61508
- Overview
- Datasheet
- Alternative numbers
- Comments
Type of protection | intrinsic safety |
Use in the hazardous area | see instruction manuals |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 В°C (167 В°F) T5 : 90 В°C (194 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 75 В°C (167 В°F) T5 : 90 В°C (194 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 В°C (149 В°F) T5 : 80 В°C (176 В°F) T4 : 90 В°C (194 В°F) T3 : 90 В°C (194 В°F) T2 : 90 В°C (194 В°F) T1 : 90 В°C (194 В°F) |
Degree of protection | IP67 |
Type of protection | intrinsic safety |
Mission Time (TM) | 20 a |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 В°C (167 В°F) T5 : 90 В°C (194 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 75 В°C (167 В°F) T5 : 90 В°C (194 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 В°C (149 В°F) T5 : 80 В°C (176 В°F) T4 : 90 В°C (194 В°F) T3 : 90 В°C (194 В°F) T2 : 90 В°C (194 В°F) T1 : 90 В°C (194 В°F) |
Sensing face | PBT |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Assured operating distance | 0 ... 2.4 mm |
Time delay before availability | ≤ 1.1 ms |
Type of protection | intrinsic safety |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Reduction factor rAl | 0.5 |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Safety Integrity Level (SIL) | SIL 2 |
Effective internal inductance | max. 100 µH A cable length of 10 m is considered. |
Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
CE marking | [*PD-Z02586A*] |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. |
Switching state indicator | LED, yellow |
Reduction factor rBrass | 0.6 |
UL approval | cULus Listed, General Purpose |
Connector housing | metal |
Actual operating distance | 2.7 ... 3.3 mm typ. |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
CE marking | [*PD-Z02585A*] |
Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Switching frequency | 0 ... 3 kHz |
Installation | flush mountable |
Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
CE marking | [*PD-Z02585A*] |
Short-circuit protection | yes |
Diagnostic Coverage (DC) | 0 % |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Type of protection | intrinsic safety |
Connection (system side) | 4-pin, M12 x 1 connector |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Reduction factor rSt37 | 1.3 |
Type of protection | intrinsic safety |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Reverse polarity protection | reverse polarity protected |
Hysteresis | typ. 5 % |
CSA approval | cCSAus Listed, General Purpose |
Reduction factor r304 | 1 |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 В°C (194 В°F) |
Rated operating distance | 3 mm |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 В°C (194 В°F) |
Reduction factor rCu | 0.4 |
Equipment protection level | Ga , Gb , Gc (ic) , Da , Mb |
Nominal voltage | 8 V |
Effective internal inductance | max. 100 µH The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) Note: Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 В°C). The temperature range specified here (up to +100В°C) only applies to sensors with part no. 2239**. |
Housing material | PBT |
Switching function | 2 x normally closed (NC) |
Output type | NAMUR |
Output type | 2-wire |
MTTFd | 1470 a |
CE marking | [*PD-Z02585A*] |
People also buy
Comments
No comments yet