Pepperl+Fuchs NCN3-F31K-N4-B13-S
Inductive sensor

Pepperl+Fuchs NCN3-F31K-N4-B13-S
  • Direct mounting on standard actuators
  • Fixed setting
  • EC-Type Examination Certificate TГњV99 ATEX 1479X
  • Screw terminals
  • Usable up to SIL 2 acc. to IEC 61508
  • LEDs for switching state of sensor and solenoid valve
  • Valve LEDs disconnectable
Item Number: NCN3-F31K-N4-B13-S
173.71
-
+
Total price: 173.71
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 20 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 70 В°C (158 В°F)
T5 : 85 В°C (185 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 20 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 70 В°C (158 В°F)
T5 : 85 В°C (185 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 20 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 65 В°C (149 В°F)
T5 : 80 В°C (176 В°F)
T4 : 90 В°C (194 В°F)
T3 : 90 В°C (194 В°F)
T2 : 90 В°C (194 В°F)
T1 : 90 В°C (194 В°F)
Nominal voltage8 V
Switching frequency0 ... 3 kHz
Type of protectionintrinsic safety
Currentmax. 240 mA
Equipment protection levelGa , Gb , Gc (ic) , Mb
Reduction factor rBrass 0.6
NoteLED switch-off
Degree of protectionIP67
Core cross-section (valve side)like core cross section (system side)
Maximum values of the valve circuitThe value applies to each valve circuit.
A cable length of 10 m is considered.
Short-circuit protectionno
Time delay before availability 1.1 ms
Type of protectionintrinsic safety
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Voltagemax. 32 V DC
Sensing facePBT
Rated operating distance3 mm
Reverse polarity protectionreverse polarity protected
Tightening torque, housing screws1 Nm
Tightening torque, cable glandM20 x 1.5 ; max. 7 Nm
Reduction factor rAl 0.5
Reverse polarity protectionyes, with reversed output LED is out of function, therfore more power for solenoid valve
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 В°C (194 В°F)
CE marking[*PD-Z02585A*]
CE marking[*PD-Z02585A*]
Switching state indicatorLED, yellow
CE marking[*PD-Z02585A*]
Core cross-section (system side)rigid: 0.14 ... 2.5 mm2
flexible: 0.14 ... 1.5 mm2
flexible with core-end sleeve: 0.25 ... 1.5 mm2
Safety Integrity Level (SIL)SIL 2
Effective internal inductancemax. 100 andmicro;H
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Hysteresistyp. 5 %
MTTFd1470 a
Reduction factor r304 1
Effective internal inductancemax. 100 andmicro;H
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Reduction factor rCu 0.4
Short-circuit protectionyes
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
Maximum values of the valve circuitThe value applies to each valve circuit.
A cable length of 10 m is considered.
Output typeNAMUR
CE marking[*PD-Z02585A*]
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Installationflush mountable
Actuating elementStainless steel 1.4305 / AISI 303
8.5 mm x 8.5 mm x 0.5 mm
Effective internal inductancemax. 100 andmicro;H
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
CCC approvalCCC approval / marking not required for products rated 36 V
EAC conformityTR CU 012/2011
Connection (valve side)like connection (system side)
Type of protectionintrinsic safety
Connection (system side)Screw terminals, tightening torque min. 0.5 Nm
Stripped length 7 mm
Type of protectionintrinsic safety
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Output type2-wire
Reduction factor rSt37 1.3
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Assured operating distance0 ... 2.4 mm
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Maximum values of the valve circuitThe value applies to each valve circuit.
A cable length of 10 m is considered.
Storage temperature-40 ... 100 В°C (-40 ... 212 В°F)
Maximum values of the valve circuitThe value applies to each valve circuit.
A cable length of 10 m is considered.
Diagnostic Coverage (DC)0 %
Mission Time (TM)20 a
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 15 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 70 В°C (158 В°F)
T5 : 85 В°C (185 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 70 В°C (158 В°F)
T5 : 85 В°C (185 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 65 В°C (149 В°F)
T5 : 80 В°C (176 В°F)
T4 : 90 В°C (194 В°F)
T3 : 90 В°C (194 В°F)
T2 : 90 В°C (194 В°F)
T1 : 90 В°C (194 В°F)
Valve status indicatorLED, yellow
Housing materialPBT
Actual operating distance2.7 ... 3.3 mm typ.
Switching function2 x normally closed (NC)
Effective internal inductancemax. 100 andmicro;H
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Use in the hazardous areasee instruction manuals

Comments

No comments yet

Write a comment