Pepperl+Fuchs NCN3-F31K-N4-B13-S
Inductive sensor
- Direct mounting on standard actuators
- Fixed setting
- EC-Type Examination Certificate TГњV99 ATEX 1479X
- Screw terminals
- Usable up to SIL 2 acc. to IEC 61508
- LEDs for switching state of sensor and solenoid valve
- Valve LEDs disconnectable
Item Number:
NCN3-F31K-N4-B13-S
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 В°C (149 В°F) T5 : 80 В°C (176 В°F) T4 : 90 В°C (194 В°F) T3 : 90 В°C (194 В°F) T2 : 90 В°C (194 В°F) T1 : 90 В°C (194 В°F) |
Nominal voltage | 8 V |
Switching frequency | 0 ... 3 kHz |
Type of protection | intrinsic safety |
Current | max. 240 mA |
Equipment protection level | Ga , Gb , Gc (ic) , Mb |
Reduction factor rBrass | 0.6 |
Note | LED switch-off |
Degree of protection | IP67 |
Core cross-section (valve side) | like core cross section (system side) |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Short-circuit protection | no |
Time delay before availability | 1.1 ms |
Type of protection | intrinsic safety |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Voltage | max. 32 V DC |
Sensing face | PBT |
Rated operating distance | 3 mm |
Reverse polarity protection | reverse polarity protected |
Tightening torque, housing screws | 1 Nm |
Tightening torque, cable gland | M20 x 1.5 ; max. 7 Nm |
Reduction factor rAl | 0.5 |
Reverse polarity protection | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 В°C (194 В°F) |
CE marking | [*PD-Z02585A*] |
CE marking | [*PD-Z02585A*] |
Switching state indicator | LED, yellow |
CE marking | [*PD-Z02585A*] |
Core cross-section (system side) | rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2 |
Safety Integrity Level (SIL) | SIL 2 |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Hysteresis | typ. 5 % |
MTTFd | 1470 a |
Reduction factor r304 | 1 |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Reduction factor rCu | 0.4 |
Short-circuit protection | yes |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Output type | NAMUR |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Installation | flush mountable |
Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
CCC approval | CCC approval / marking not required for products rated 36 V |
EAC conformity | TR CU 012/2011 |
Connection (valve side) | like connection (system side) |
Type of protection | intrinsic safety |
Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm |
Type of protection | intrinsic safety |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Output type | 2-wire |
Reduction factor rSt37 | 1.3 |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Assured operating distance | 0 ... 2.4 mm |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Diagnostic Coverage (DC) | 0 % |
Mission Time (TM) | 20 a |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 В°C (149 В°F) T5 : 80 В°C (176 В°F) T4 : 90 В°C (194 В°F) T3 : 90 В°C (194 В°F) T2 : 90 В°C (194 В°F) T1 : 90 В°C (194 В°F) |
Valve status indicator | LED, yellow |
Housing material | PBT |
Actual operating distance | 2.7 ... 3.3 mm typ. |
Switching function | 2 x normally closed (NC) |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Use in the hazardous area | see instruction manuals |
People also buy
Comments
No comments yet