- Direct mounting on standard actuators
- Fixed setting
- EC-Type Examination Certificate T??V99 ATEX 1479X
- Screw terminals
- Usable up to SIL 2 acc. to IEC 61508
- LEDs for switching state of sensor and solenoid valve
- Valve LEDs disconnectable
Item Number:
NCN3-F31K-N4-B13-S
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 ?°C (158 ?°F) T5 : 85 ?°C (185 ?°F) T4 : 100 ?°C (212 ?°F) T3 : 100 ?°C (212 ?°F) T2 : 100 ?°C (212 ?°F) T1 : 100 ?°C (212 ?°F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 ?°C (158 ?°F) T5 : 85 ?°C (185 ?°F) T4 : 100 ?°C (212 ?°F) T3 : 100 ?°C (212 ?°F) T2 : 100 ?°C (212 ?°F) T1 : 100 ?°C (212 ?°F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 ?°C (149 ?°F) T5 : 80 ?°C (176 ?°F) T4 : 90 ?°C (194 ?°F) T3 : 90 ?°C (194 ?°F) T2 : 90 ?°C (194 ?°F) T1 : 90 ?°C (194 ?°F) |
Nominal voltage | 8 V |
Switching frequency | 0 ... 3 kHz |
Type of protection | intrinsic safety |
Current | max. 240 mA |
Equipment protection level | Ga , Gb , Gc (ic) , Mb |
Reduction factor rBrass | 0.6 |
Note | LED switch-off |
Degree of protection | IP67 |
Core cross-section (valve side) | like core cross section (system side) |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Short-circuit protection | no |
Time delay before availability | 1.1 ms |
Type of protection | intrinsic safety |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Voltage | max. 32 V DC |
Sensing face | PBT |
Rated operating distance | 3 mm |
Reverse polarity protection | reverse polarity protected |
Tightening torque, housing screws | 1 Nm |
Tightening torque, cable gland | M20 x 1.5 ; max. 7 Nm |
Reduction factor rAl | 0.5 |
Reverse polarity protection | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 ?°C (212 ?°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 ?°C (212 ?°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 ?°C (194 ?°F) |
CE marking | [*PD-Z02585A*] |
CE marking | [*PD-Z02585A*] |
Switching state indicator | LED, yellow |
CE marking | [*PD-Z02585A*] |
Core cross-section (system side) | rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2 |
Safety Integrity Level (SIL) | SIL 2 |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Hysteresis | typ. 5 % |
MTTFd | 1470 a |
Reduction factor r304 | 1 |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Reduction factor rCu | 0.4 |
Short-circuit protection | yes |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Output type | NAMUR |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Installation | flush mountable |
Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
CCC approval | CCC approval / marking not required for products rated 36 V |
EAC conformity | TR CU 012/2011 |
Connection (valve side) | like connection (system side) |
Type of protection | intrinsic safety |
Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm |
Type of protection | intrinsic safety |
Ambient temperature | -25 ... 100 ?°C (-13 ... 212 ?°F) |
Output type | 2-wire |
Reduction factor rSt37 | 1.3 |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Assured operating distance | 0 ... 2.4 mm |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Storage temperature | -40 ... 100 ?°C (-40 ... 212 ?°F) |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. |
Diagnostic Coverage (DC) | 0 % |
Mission Time (TM) | 20 a |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 ?°C (158 ?°F) T5 : 85 ?°C (185 ?°F) T4 : 100 ?°C (212 ?°F) T3 : 100 ?°C (212 ?°F) T2 : 100 ?°C (212 ?°F) T1 : 100 ?°C (212 ?°F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 ?°C (158 ?°F) T5 : 85 ?°C (185 ?°F) T4 : 100 ?°C (212 ?°F) T3 : 100 ?°C (212 ?°F) T2 : 100 ?°C (212 ?°F) T1 : 100 ?°C (212 ?°F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 65 ?°C (149 ?°F) T5 : 80 ?°C (176 ?°F) T4 : 90 ?°C (194 ?°F) T3 : 90 ?°C (194 ?°F) T2 : 90 ?°C (194 ?°F) T1 : 90 ?°C (194 ?°F) |
Valve status indicator | LED, yellow |
Housing material | PBT |
Actual operating distance | 2.7 ... 3.3 mm typ. |
Switching function | 2 x normally closed (NC) |
Effective internal inductance | max. 100 andmicro;H The value is applicable for one sensor circuit. A cable length of 10 m is considered. |
Use in the hazardous area | see instruction manuals |
Buy Pepperl+Fuchs NCN3-F31K-N4-B13-S with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is fast developing company in automation parts. We can help you save time and reject from many other suppliers due to the large variety of offering goods. Our sales are spread all over the world. Due to providing low prices you can save money. A personal manager will attend you at all stages of the deal. We respect your needs and are interested in their total satisfaction.