Pepperl+Fuchs NEN40-30GM60-E2-V1
Inductive sensor
Series: Cylindrical type, Housing diameter: 30 mm, Housing material: chromium plated brass, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Item Number:
NEN40-30GM60-E2-V1
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
General specifications | ||
Switching element function | PNP | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 32.4 mm | |
Reduction factor rAl | 0.36 | |
Reduction factor rCu | 0.32 | |
Reduction factor r304 | 0.69 | |
Nominal ratings | ||
Installation conditions | ||
A | in aluminum: 25 mm in steel 1.0037 (St37): 35 mm in brass 25 mm in stainless steel 20 mm | |
B | 40 mm | |
C | 120 mm | |
F | 150 mm | |
Operating voltage | 10 ... 30 V | |
Switching frequency | 0 ... 100 Hz | |
Hysteresis | typ. 5% | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | less than or equal to 2 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.1 mA typ. 0.1 mA at 25 °C | |
No-load supply current | less than or equal to 10 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 211 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated less than or equal to 36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector M12 x 1 , 4-pin | |
Housing material | chromium plated brass | |
Sensing face | PBT | |
Housing diameter | 30 mm | |
Degree of protection | IP67 |