Pepperl+Fuchs NJ1,5-8-N-Y18812
Inductive sensor

Pepperl+Fuchs NJ1,5-8-N-Y18812
  • With special adjustment
Item Number: NJ1,5-8-N-Y18812
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Degree of protectionIP67
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Mission Time (TM)20 a
CertificatePF 13 CERT 2895 X
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
MTTFd11467 a
Core cross-section0.14 mm2
CE marking[*PD-Z02585A*]
Switching functionNormally closed (NC)
Appropriate typeNJ1,5-8-N..
Output typeNAMUR
Effective internal capacitance Cimax. 20 nF ; a cable length of 10 m is considered.
Reduction factor rAl 0.4
CSA approvalcCSAus Listed, General Purpose
Effective internal inductance Limax. 50 µH ; A cable length of 10 m is considered.
Nominal voltage8 V
ATEX marking II 3G Ex ic IIC T6…T1 Gc
The Ex-significant identification is on the enclosed adhesive label
CE marking[*PD-Z02586A*]
Output type2-wire
Appropriate typeNJ1,5-8-N..
Hysteresis0.1 mm
Effective internal inductancemax. 50 µH ; a cable length of 10 m is considered.
UL approvalcULus Listed, General Purpose
ATEX marking II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label.
Effective internal capacitancemax. 20 nF ; a cable length of 10 m is considered.
Maximum permissible ambient temperature
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
Connection typecable PUR , 6 m
Effective internal inductancemax. 50 µH ; a cable length of 10 m is considered.
Assured operating distance0 ... 0.97 mm
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ""ic"" Use is restricted to the following stated conditions
Housing materialbrass
Effective internal inductancemax. 50 µH ; A cable length of 10 m is considered.
Reduction factor rCu 0.3
Rated operating distance1.5 mm
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Standard conformityEN 60079-15:2003 Ignition protection category ""n""
Use is restricted to the following stated conditions
Effective internal capacitancemax. 20 nF ; a cable length of 10 m is considered.
Installationflush
Switching frequency0 ... 2000 Hz
Effective internal capacitancemax. 20 nF ; a cable length of 10 m is considered.
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
ATEX marking II 2G Ex ia IIC T6…T1 Gb The Ex-related marking can also be printed on the enclosed label.
Sensing facePBT
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Diagnostic Coverage (DC)0 %
CE marking[*PD-Z02585A*]
Use in the hazardous areasee instruction manuals
Reduction factor r304 0.85

Comments

No comments yet

Write a comment