Pepperl+Fuchs NJ2-11-N-G-Y132813
Inductive sensor
- Comfort series
- Overview
- Comments
Reduction factor rCu | 0.3 |
Connection type | cable PVC , 10 m |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 81 В°C (177.8 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 63 В°C (145.4 В°F) |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. |
Output type | NAMUR |
Core cross-section | 0.34 mm2 |
MTTFd | 5887 a |
Output type | 2-wire |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Sensing face | PVDF |
Type of protection | intrinsic safety |
Mission Time (TM) | 20 a |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 81 В°C (177.8 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 63 В°C (145.4 В°F) |
Switching function | Normally closed (NC) |
Diagnostic Coverage (DC) | 0 % |
Nominal voltage | 8 V |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 76 В°C (168.8 В°F) T5 : 91 В°C (195.8 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 73 В°C (163.4 В°F) T5 : 88 В°C (190.4 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 62 В°C (143.6 В°F) T5 : 77 В°C (170.6 В°F) T4 : 81 В°C (177.8 В°F) T3 : 81 В°C (177.8 В°F) T2 : 81 В°C (177.8 В°F) T1 : 81 В°C (177.8 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 54 В°C (129.2 В°F) T5 : 63 В°C (145.4 В°F) T4 : 63 В°C (145.4 В°F) T3 : 63 В°C (145.4 В°F) T2 : 63 В°C (145.4 В°F) T1 : 63 В°C (145.4 В°F) |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. |
Installation | flush |
CE marking | [*PD-Z02585A*] |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. |
Reduction factor r304 | 0.85 |
Type of protection | intrinsic safety |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Hysteresis | 0.5 ... 3.5 typ. 2 % |
Reduction factor rAl | 0.4 |
Rated operating distance | 2 mm |
Type of protection | intrinsic safety |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
Use in the hazardous area | see instruction manuals |
Degree of protection | IP66 / IP68 |
CE marking | [*PD-Z02585A*] |
Effective internal inductance | max. 50 µH A cable length of 10 m is considered. |
Type of protection | intrinsic safety |
Housing material | Stainless steel 1.4305 / AISI 303 |
Equipment protection level | Ga , Gb , Da , Mb |
Actual operating distance | 1.8 ... 2.2 mm |
Assured operating distance | 0 ... 1.62 mm |
Switching frequency | 0 ... 3000 Hz |
People also buy
Comments
No comments yet