Pepperl+Fuchs NJ2-12GK-SN-10M
Inductive sensor

Series: Cylindrical type, Housing diameter: 12 mm, Housing material: PP, Rated operating distance: 2 mm, Connection type: cable silicone , 10 m, Output type: 2-wire, Installation: flush, Type of voltage: DC

Item Number:
NJ2-12GK-SN-10M
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
General specifications | ||
Switching element function | NAMUR, NC | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | Safety Function | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the exida Functional Safety Assessment document which is available on www.PEPPERL+FUCHS.com as an integral part of this product's documentation. | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Operating voltage | 5 ... 25 V 1) | |
Switching frequency | 0 ... 2000 Hz | |
Suitable for 2:1 technology | yes , with reverse polarity protection diode | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | less than or equal to 1 mA | |
Functional safety related parameters | ||
MTTFd | 7660 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165F | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated less than or equal to 36 V | |
Ambient conditions | ||
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable silicone , 10 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PP | |
Sensing face | PP | |
Housing diameter | 12 mm | |
Degree of protection | IP68 | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G- 2G- 1D |
People also buy
Comments
No comments yet