- 2 mm flush
- Usable up to SIL 2 acc. to IEC 61508
Item Number:
NJ2-V3-N-0,075M
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Installationflush
Assured operating distance | 0 ... 1.62 mm |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Effective internal capacitance | max. 40 nF ; a cable length of 10 m is considered. |
Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
Output type | 2-wire |
Appropriate type | NJ 2-V3-N ... |
Output type | NAMUR |
Hysteresis | 0.01 ... 0.1 mm |
Appropriate type | NJ 2-V3-N ... |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
MTTFd | 11775 a |
Diagnostic Coverage (DC) | 0 % |
Reduction factor r304 | 0.7 |
Switching function | Normally closed (NC) |
Core cross-section | 0.14 mm2 |
Effective internal capacitance | max. 40 nF ; a cable length of 10 m is considered. |
Switching frequency | 0 ... 1000 Hz |
Housing material | PBT |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. |
Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
Degree of protection | IP67 |
Rated operating distance | 2 mm |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
Effective internal capacitance | max. 40 nF ; a cable length of 10 m is considered. |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Sensing face | PBT |
Connection type | cable PVC , 75 mm , Wire ends, 3 mm, stripped and tin-plated |
ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Reduction factor rAl | 0.25 |
CE marking | [*PD-Z02585A*] |
ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Appropriate type | NJ 2-V3-N ... |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
EAC conformity | TR CU 012/2011 |
Use in the hazardous area | see instruction manuals |
CE marking | [*PD-Z02585A*] |
Reduction factor rCu | 0.2 |
CE marking | [*PD-Z02585A*] |
Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Mission Time (TM) | 20 a |
CSA approval | cCSAus Listed, General Purpose |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
Buy Pepperl+Fuchs NJ2-V3-N-0,075M with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. provides complete industrial automation solutions. With a wide selection of products and efficient delivery options, we meet your needs effectively. Our focus on quality and customer satisfaction distinguishes us. Experience our exceptional service and support for your automation needs.