Pepperl+Fuchs NJ5-30GK-S1N-15M
Inductive sensor

Pepperl+Fuchs NJ5-30GK-S1N-15M
We ship to United States of America!
  • Nonferrous targets
  • 5 mm flush in ST37 / 1.0037
  • Usable up to SIL 3 acc. to IEC 61508
  • ATEX approval Ex-i and Ex-nA/tc for zone 0-2 and zone 20-22
  • Degree of protection IP68
Item Number: NJ5-30GK-S1N-15M
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +
CE marking[*PD-Z02585A*]
Connection typecable silicone , 15 m
Effective internal capacitancemax. 100 nF
A cable length of 10 m is considered.
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
CE marking[*PD-Z02586A*]
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
using an amplifier in accordance with EN 60947-5-6 : 58 В°C (136.4 В°F)
at UBmax = 9 V , RV = 562 andOmega; : 58 В°C (136.4 В°F)
MTTFd11850 a
Equipment protection levelGa , Gb , Gc (nA) , Da , Dc , Mb
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax
Reduction factor r304 0
Type of protectionintrinsic safety
Safety Integrity Level (SIL)up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.
Consider the ""exida Functional Safety Assessment"" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Assured operating distance0 ... 4.05 mm
Nominal voltage8.2 V
Type of protection""n""
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 В°C (176 В°F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 В°C (141.8 В°F)
Diagnostic Coverage (DC)0 %
CE marking[*PD-Z02586A*]
Effective internal capacitancemax. 100 nF
A cable length of 10 m is considered.
Reduction factor rCu 1
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 В°C (176 В°F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 В°C (141.8 В°F)
CCC approvalCCC approval / marking not required for products rated 36 V
Switching frequency0 ... 150 Hz
Effective internal inductancemax. 200 andmicro;H
A cable length of 10 m is considered.
Housing materialCrastin (PBTB), black
Type of protectionintrinsic safety
Core cross-section0.75 mm2
Output typeNAMUR with safety function
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 73 В°C (163.4 В°F)
T5 : 88 В°C (190.4 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 16 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 69 В°C (156.2 В°F)
T5 : 84 В°C (183.2 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 16 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 51 В°C (123.8 В°F)
T5 : 66 В°C (150.8 В°F)
T4 : 80 В°C (176 В°F)
T3 : 80 В°C (176 В°F)
T2 : 80 В°C (176 В°F)
T1 : 80 В°C (176 В°F)
at Ui = 16 V , Ii = 76 mA , Pi = 242 mW ,
T6 : 39 В°C (102.2 В°F)
T5 : 54 В°C (129.2 В°F)
T4 : 61 В°C (141.8 В°F)
T3 : 61 В°C (141.8 В°F)
T2 : 61 В°C (141.8 В°F)
T1 : 61 В°C (141.8 В°F)
Type of protectionintrinsic safety
Type of protectionintrinsic safety
Use in the hazardous areasee instruction manuals
Effective internal capacitancemax. 100 nF
A cable length of 10 m is considered.
Switching functionNormally open (NO)
Sensing faceCrastin (PBTB), black
CE marking[*PD-Z02585A*]
Effective internal capacitancemax. 100 nF
A cable length of 10 m is considered.
Output type2-wire
Installationflush in mild steel
EAC conformityTR CU 012/2011
Effective internal inductancemax. 200 andmicro;H
A cable length of 10 m is considered.
Reduction factor rAl 1
Mission Time (TM)20 a
Type of protectionProtection by enclosure ""tc""
UL approvalcULus Listed, General Purpose
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values. :
using an amplifier in accordance with EN 60947-5-6 : 58 В°C (136.4 В°F)
at UBmax = 9 V , RV = 562 andOmega; : 58 В°C (136.4 В°F)
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Safety Integrity Level (SIL)SIL 3
Rated operating distance5 mm
Noteonly for non-ferrous metal
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
Effective internal inductancemax. 200 andmicro;H
A cable length of 10 m is considered.
CE marking[*PD-Z02585A*]
Effective internal inductancemax. 200 andmicro;H
A cable length of 10 m is considered.
CE marking[*PD-Z02585A*]
Degree of protectionIP68

Buy Pepperl+Fuchs NJ5-30GK-S1N-15M with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is fast developing company in supplying industrial automation equipment. Our product range spreads from simple electronic components and switches to high-voltage complex systems. We supply equipment in Europe and throughout the world. The quality of the products we carry meets all international standards and the price is minimal compared to our competitors. We will keep You informed at all stages of the deal. We adhere to the principle of win–win, and our purpose is mutually advantageous long-term cooperation.

Comments

No comments yet