Pepperl+Fuchs NJ5-30GK-S1N-15M
Inductive sensor
We ship to United States of America!
- Nonferrous targets
- 5 mm flush in ST37 / 1.0037
- Usable up to SIL 3 acc. to IEC 61508
- ATEX approval Ex-i and Ex-nA/tc for zone 0-2 and zone 20-22
- Degree of protection IP68
Item Number:
NJ5-30GK-S1N-15M
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
CE marking | [*PD-Z02585A*] |
Connection type | cable silicone , 15 m |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
CE marking | [*PD-Z02586A*] |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. using an amplifier in accordance with EN 60947-5-6 : 58 В°C (136.4 В°F) at UBmax = 9 V , RV = 562 andOmega; : 58 В°C (136.4 В°F) |
MTTFd | 11850 a |
Equipment protection level | Ga , Gb , Gc (nA) , Da , Dc , Mb |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax |
Reduction factor r304 | 0 |
Type of protection | intrinsic safety |
Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the ""exida Functional Safety Assessment"" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
Assured operating distance | 0 ... 4.05 mm |
Nominal voltage | 8.2 V |
Type of protection | ""n"" |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 В°C (176 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 В°C (141.8 В°F) |
Diagnostic Coverage (DC) | 0 % |
CE marking | [*PD-Z02586A*] |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. |
Reduction factor rCu | 1 |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 80 В°C (176 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 61 В°C (141.8 В°F) |
CCC approval | CCC approval / marking not required for products rated 36 V |
Switching frequency | 0 ... 150 Hz |
Effective internal inductance | max. 200 andmicro;H A cable length of 10 m is considered. |
Housing material | Crastin (PBTB), black |
Type of protection | intrinsic safety |
Core cross-section | 0.75 mm2 |
Output type | NAMUR with safety function |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 В°C (163.4 В°F) T5 : 88 В°C (190.4 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 69 В°C (156.2 В°F) T5 : 84 В°C (183.2 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 51 В°C (123.8 В°F) T5 : 66 В°C (150.8 В°F) T4 : 80 В°C (176 В°F) T3 : 80 В°C (176 В°F) T2 : 80 В°C (176 В°F) T1 : 80 В°C (176 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 39 В°C (102.2 В°F) T5 : 54 В°C (129.2 В°F) T4 : 61 В°C (141.8 В°F) T3 : 61 В°C (141.8 В°F) T2 : 61 В°C (141.8 В°F) T1 : 61 В°C (141.8 В°F) |
Type of protection | intrinsic safety |
Type of protection | intrinsic safety |
Use in the hazardous area | see instruction manuals |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. |
Switching function | Normally open (NO) |
Sensing face | Crastin (PBTB), black |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. |
Output type | 2-wire |
Installation | flush in mild steel |
EAC conformity | TR CU 012/2011 |
Effective internal inductance | max. 200 andmicro;H A cable length of 10 m is considered. |
Reduction factor rAl | 1 |
Mission Time (TM) | 20 a |
Type of protection | Protection by enclosure ""tc"" |
UL approval | cULus Listed, General Purpose |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. : using an amplifier in accordance with EN 60947-5-6 : 58 В°C (136.4 В°F) at UBmax = 9 V , RV = 562 andOmega; : 58 В°C (136.4 В°F) |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax |
Safety Integrity Level (SIL) | SIL 3 |
Rated operating distance | 5 mm |
Note | only for non-ferrous metal |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
Effective internal inductance | max. 200 andmicro;H A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Effective internal inductance | max. 200 andmicro;H A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Degree of protection | IP68 |
Buy Pepperl+Fuchs NJ5-30GK-S1N-15M with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is fast developing company in supplying industrial automation equipment. Our product range spreads from simple electronic components and switches to high-voltage complex systems. We supply equipment in Europe and throughout the world. The quality of the products we carry meets all international standards and the price is minimal compared to our competitors. We will keep You informed at all stages of the deal. We adhere to the principle of win–win, and our purpose is mutually advantageous long-term cooperation.
People also buy
Comments
No comments yet