Pepperl+Fuchs NJ6-22-N-G-15M
Inductive sensor

Pepperl+Fuchs NJ6-22-N-G-15M
We ship to United States of America!
  • Comfort series
  • 6 mm flush
  • Usable up to SIL 2 acc. to IEC 61508
Item Number: NJ6-22-N-G-15M
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview +
  • Comments +
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure ""tc"" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
CE marking[*PD-Z02585A*]
CE marking[*PD-Z02586A*]
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Use in the hazardous areasee instruction manuals
Effective internal capacitancemax. 130 nF ; a cable length of 10 m is considered.
Switching functionNormally closed (NC)
Core cross-section0.75 mm2
Output typeNAMUR
Installationflush
Diagnostic Coverage (DC)0 %
Mission Time (TM)20 a
ATEX marking II 2G Ex ia IIC T6…T1 Gb
The Ex-related marking can also be printed on the enclosed label.
CCC approvalCCC approval / marking not required for products rated ≤36 V
Effective internal capacitancemax. 130 nF ; a cable length of 10 m is considered.
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Sensing facePBT
ATEX marking II 3G Ex ic IIC T6…T1 Gc
The Ex-related marking can also be printed on the enclosed label.
Hysteresistyp. %
UL approvalcULus Listed, General Purpose
GeneralThe corresponding datasheets, declarations of conformity, EU type examination certificates, certificates, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents are available at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Connection typecable PVC , 15 m
Effective internal capacitancemax. 130 µF
A cable length of 10 m is considered.
Degree of protectionIP68
ATEX marking II 3D Ex tc IIIC T80В°C Dc
The Ex-related marking can also be printed on the enclosed label.
Effective internal inductancemax. 100 µH ; A cable length of 10 m is considered.
Reduction factor rAl 0.4
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
MTTFd4566 a
Reduction factor r304 0.85
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
CertificatePF 13 CERT 2895 X
CE marking[*PD-Z02586A*]
Effective internal inductancemax. 100 µH
A cable length of 10 m is considered.
Rated operating distance6 mm
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Reduction factor rCu 0.3
Appropriate typeNJ 6-22-N...
Housing materialStainless steel 1.4305 / AISI 303
Switching frequency0 ... 2000 Hz
Nominal voltage8 V
Output type2-wire
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Appropriate typeNJ 6-22-N...
Assured operating distance0 ... 4.86 mm
CSA approvalcCSAus Listed, General Purpose
CE marking[*PD-Z02585A*]
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection category ""ic""
Use is restricted to the following stated conditions

Buy Pepperl+Fuchs NJ6-22-N-G-15M with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online electronic supply store. We offer only original products with all manufacturer's warranty. All your orders and products can be shipped in one delivery. Good price and good delivery times are our main goals. We always make open communication with our customers. Make an order and we will give you the best possible proposal.

Comments

No comments yet

Write a comment