Pepperl+Fuchs NRB20-U1-E2-IO
Inductive sensor
- 20 mm flush
- Reduction factor = 1
- Magnetic field resistant
- IO-link interface for service and process data
- Switch point mode or window mode can be set
- Switching function, stability alarm and pulse extension can be set
- 4-way LED indicator
- Quick mounting bracket
Item Number:
NRB20-U1-E2-IO
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
SIO mode support | yes |
Operating voltage indicator | LED, green |
Constant magnetic field | 200 mT |
Core cross-section | up to 2.5 mm2 |
Diagnostic Coverage (DC) | 0 % |
Housing base | plastic |
Reduction factor r304 | 1 |
Connection type | screw terminals |
Compatible master port type | A |
Output type | 3-wire |
No-load supply current | 20 mA |
Note | Tightening torque: 1.8 Nm (housing) |
Reduction factor rAl | 1 |
Protection class | II |
Interface type | IO-Link ( via C/Q = terminal 4 ) |
Near operating distance | 15 mm (can be activated by software) |
Output polarity | DC |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Device ID | 0x201005 (2101253) |
IO-Link Revision | 1.1 |
Status indicator | LED, yellow |
Housing material | PA/metal with epoxy powder coating |
Sensing face | PA |
Assured operating distance | 0 ... 16.2 mm |
Process data witdh | Process data input (control system side): 2 Bit Process data output (control system side): none |
Switching function | Normally open/closed (NO/NC) programmable |
Degree of protection | IP67 |
Output type | PNP |
Reverse polarity protection | reverse polarity protected |
Installation | flush |
Hysteresis | typ. 3 % |
CCC approval | CCC approval / marking not required for products rated 36 V |
Switching frequency | 0 ... 440 Hz (switch point mode) 0 ... 10 Hz (window mode, switch point mode with stability alarm) |
Reduction factor rCu | 1 |
Time delay before availability | max. 150 ms |
MTTFd | 701 a |
Mass | 275 g |
Rated operating distance | 20 mm (factory setting) |
Off-state current | 0 ... 0.5 mA typ. 60 andmicro;A at 25 В°C |
Default setting | operating mode = switch point mode with stability alarm switching function = Normally open (NO) switching distance = 20 mm |
Voltage drop | 0.5 V |
UL approval | cULus Listed, General Purpose Class 2 power source |
Mission Time (TM) | 20 a |
Alternating magnetic field | 200 mT |
Operating voltage | 10 ... 30 V DC |
Min. cycle time | 2.3 ms |
Transfer rate | COM 2 (38.4 kBaud) |
Short-circuit protection | pulsing |
Reduction factor rSt37 | 1 |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Operating current | 0 ... 200 mA |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
People also buy
Comments
No comments yet