Pepperl+Fuchs NRN30-30GS50-E2-IO
Inductive sensor

Pepperl+Fuchs NRN30-30GS50-E2-IO
  • 30 mm non-flush
  • Reduction factor = 1
  • Magnetic field resistant
  • IO-link interface for service and process data
  • Switch point mode or window mode can be set
  • Switching function, stability alarm and pulse extension can be set
Item Number: NRN30-30GS50-E2-IO
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Status indicatorLED yellow
Interface typeIO-Link ( via C/Q )
Near operating distance20 mm (can be activated by software)
Device ID0x201106 (2101510)
Voltage drop 0.5 V
Rated operating distance30 mm (factory setting)
No-load supply current 15 mA
Operating current0 ... 200 mA
Compatible master port typeA
Reduction factor rSt37 1
Time delay before availabilitymax. 150 ms
Hysteresistyp. 3 %
Min. cycle time2.3 ms
MTTFd360 a
IO-Link Revision1.1
Housing materialStainless steel 1.4305 / AISI 303
Process data witdhProcess data input (control system side): 2 Bit
Process data output (control system side): none
Assured operating distance0 ... 24.3 mm
SIO mode supportyes
Core cross-section0.34 mm2
Diagnostic Coverage (DC)0 %
Protection classII
Mass170 g
Alternating magnetic field200 mT
UL approvalcULus Listed, General Purpose
Class 2 power source
Connection typecable PVC , 2 m
Short-circuit protectionpulsing
Installationnon-flush
Default settingoperating mode = switch point mode with stability alarm
switching function = Normally open (NO)
switching distance = 30 mm
Reverse polarity protectionreverse polarity protected
Scope of delivery2 self locking nuts in scope of delivery
Output type3-wire
Reduction factor rAl 1
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Operating voltage10 ... 30 V DC
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Switching functionNormally open/closed (NO/NC) programmable
CCC approvalCCC approval / marking not required for products rated 36 V
Off-state current0 ... 0.5 mA typ. 60 andmicro;A at 25 В°C
Sensing facePBT
Reduction factor r304 1
Mission Time (TM)20 a
Constant magnetic field200 mT
Reduction factor rCu 1
Degree of protectionIP67
Output polarityDC
Switching frequency0 ... 680 Hz (switch point mode)
0 ... 50 Hz (window mode, switch point mode with stability alarm)
Transfer rateCOM 2 (38.4 kBaud)
Output typePNP

Comments

No comments yet