Pepperl+Fuchs NSB2-12GM45-2E2-V1-M1-S2D2
Inductive sensor

Pepperl+Fuchs NSB2-12GM45-2E2-V1-M1-S2D2
  • No unusable area
  • 2 mm flush
  • Use of standard metallic actuating surfaces
  • Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
  • LED for switching state and fault indication
  • Safety outputs OSSD
  • TГњV certified
  • E1-Type approval
  • Extended temperature range
    -40 ... +85 В°C
Item Number: NSB2-12GM45-2E2-V1-M1-S2D2
133.75
-
+
Total price: 133.75
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Reduction factor rAl 0.6
Reverse polarity protectionreverse polarity protected
Assured release distance of a PDDB3 mm
Hysteresistyp. 5%
Mass18 g
Housing materialbrass, nickel-plated
Reduction factor rBrass 0.6
Rated insulation voltage30 V
Switching state indicatorLED, yellow
MTTFd> 7500 a
Overload resistanceyes
Output type4-wire
Off-state current0 ... 0.5 mA
Time delay before availability≤ 300 ms
Operating voltage18 ... 30 V
Reduction factor r304 0.9
Output polarityDC
Output typePNP
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Altitude≤ 2000 m above MSL
Switching function2 x normally open (NO)
CCC approvalCCC approval / marking not required for products rated ≤36 V
Performance level (PL)PL d
Short-circuit protectionpulsing
E1 Type approval10R-04
Installationflush
Connection typeConnector plug M12 x 1 , 4-pin
Actuating elementReference target according EN IEC 60947-5-2 (FE360 - ST37K)
12 mm x 12 mm x 1 mm
Voltage drop≤ 3 V
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
Error indicatorLED, red
Diagnostic Coverage (DC)min. 60 %
CategoryCat. 2
Degree of protectionIP68 / IP69
Ambient temperature-40 ... 85 В°C (-40 ... 185 В°F)
Assured operating distance0 ... 1.62 mm
Rated operating voltage24 V
No-load supply current≤ 15 mA
Safety Integrity Level (SIL)SIL 2
Rated operating distance2 mm
Switching frequency0 ... 30 Hz
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Operating current1 ... 30 mA per output
Reduction factor rCu 0.45
Mission Time (TM)20 a

Comments

No comments yet

Write a comment