Pepperl+Fuchs NSB5-18GM45-2E2-V1-S2D2
Inductive sensor
- No unusable area
- 5 mm flush
- Use of standard metallic actuating surfaces
- Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
- LED for switching state and fault indication
- Safety outputs OSSD
- TГњV certified
Item Number:
NSB5-18GM45-2E2-V1-S2D2
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Performance level (PL) | PL d |
Assured release distance of a PDDB | 7.5 mm |
No-load supply current | ≤ 15 mA |
Mass | 45 g |
Reduction factor rBrass | 0.55 |
Diagnostic Coverage (DC) | min. 60 % |
Output type | 4-wire |
Switching frequency | 0 ... 30 Hz |
MTTFd | > 7500 a |
Category | Cat. 2 |
Off-state current | 0 ... 0.5 mA |
Degree of protection | IP68 / IP69 |
Overload resistance | yes |
Time delay before availability | ≤ 300 ms |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Switching function | 2 x normally open (NO) |
Reverse polarity protection | reverse polarity protected |
Reduction factor r304 | 0.85 |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Mission Time (TM) | 20 a |
Rated operating voltage | 24 V |
Housing material | brass, nickel-plated |
Actuating element | Reference target according EN IEC 60947-5-2 (FE360 - ST37K) 18 mm x 18 mm x 1 mm |
Connection type | Connector plug M12 x 1 , 4-pin |
Scope of delivery | 2 self locking nuts in scope of delivery |
Error indicator | LED, red |
Reduction factor rAl | 0.5 |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Safety Integrity Level (SIL) | SIL 2 |
Operating current | 1 ... 30 mA per output |
Output polarity | DC |
Reduction factor rCu | 0.4 |
Hysteresis | typ. 5% |
Switching state indicator | LED, yellow |
Altitude | ≤ 2000 m above MSL |
Output type | PNP |
Rated insulation voltage | 30 V |
Operating voltage | 18 ... 30 V |
Assured operating distance | 0 ... 4.05 mm |
Voltage drop | ≤ 3 V |
Installation | flush |
Short-circuit protection | pulsing |
Sensing face | PBT |
Rated operating distance | 5 mm |