Pepperl+Fuchs NSN4-12GH45-2E2-V1-M1-S2D2
Inductive sensor
- No unusable area
- 4 mm non-flush
- Use of standard metallic actuating surfaces
- Applications up to Cat. 2, PLd/SIL 2 possible (can be used redundantly up to Cat. 3, PLe/SIL 3)
- LED for switching state and fault indication
- Safety outputs OSSD
- TГњV certified
- E1-Type approval
- Extended temperature range
-40 ... +85 В°C
Item Number:
NSN4-12GH45-2E2-V1-M1-S2D2
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Switching state indicator | LED, yellow |
Rated operating voltage | 24 V |
Hysteresis | typ. 5% |
Safety Integrity Level (SIL) | SIL 2 |
Reduction factor rCu | 0.5 |
Connection type | Connector plug M12 x 1 , 4-pin |
Mission Time (TM) | 20 a |
Assured operating distance | 0 ... 3.24 mm |
Output type | PNP |
Altitude | ≤ 2000 m above MSL |
Output type | 4-wire |
Sensing face | PBT |
Time delay before availability | ≤ 300 ms |
No-load supply current | ≤ 15 mA |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Housing material | stainless steel 1.4404 / AISI 316L |
Reduction factor r304 | 0.9 |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Actuating element | Reference target according EN IEC 60947-5-2 (FE360 - ST37K) 12 mm x 12 mm x 1 mm |
Switching function | 2 x normally open (NO) |
Rated operating distance | 4 mm |
Off-state current | 0 ... 0.5 mA |
Operating voltage | 18 ... 30 V |
Short-circuit protection | pulsing |
Ambient temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Reduction factor rBrass | 0.6 |
Degree of protection | IP68 / IP69 |
Mass | 18 g |
Operating current | 1 ... 30 mA per output |
Assured release distance of a PDDB | 6 mm |
Temperature drift | ≤ 10 % below - 25В°C ≤ 20% |
Voltage drop | ≤ 3 V |
Rated insulation voltage | 30 V |
Reverse polarity protection | reverse polarity protected |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Performance level (PL) | PL d |
Scope of delivery | Supplied with 2 nuts |
MTTFd | > 7500 a |
Category | Cat. 2 |
Reduction factor rAl | 0.55 |
Error indicator | LED, red |
Output polarity | DC |
E1 Type approval | 10R-04 |
Installation | non-flush |
Switching frequency | 0 ... 30 Hz |
Diagnostic Coverage (DC) | min. 60 % |
Overload resistance | yes |
People also buy
Comments
No comments yet