Pepperl+Fuchs OBD1000-R100-2EP-IO-0,3M-V31
Diffuse mode sensor

Pepperl+Fuchs OBD1000-R100-2EP-IO-0,3M-V31
  • Miniature design with versatile mounting options
  • Extended temperature range
    -40В°C ... 60В°C
  • High degree of protection IP69K
  • IO-link interface for service and process data
Item Number: OBD1000-R100-2EP-IO-0,3M-V31
87.91
-
+
Total price: 87.91
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Ambient light limitEN 60947-5-2
Reference targetstandard white, 100 mm x 100 mm
Detection range2 ... 1000 mm
Massapprox. 10 g
Usage categoryDC-12 and DC-13
Process data witdhProcess data input 1 Bit
Process data output 2 Bit
Light sourceLED
Diameter of the light spotapprox. 65 mm at a distance of 1000 mm
Cable length0.3 m
Interface typeIO-Link ( via C/Q = pin 4 )
Min. cycle time2.3 ms
Light typemodulated visible red light
Housing height37.1 mm
No-load supply current< 25 mA at 24 V supply voltage
Angle of divergence3.7 В°
Ripplemax. 10 %
Switching currentmax. 100 mA , resistive load
Adjustment range50 ... 1000 mm
Connectionfixed cable 300 mm with M8 x 1 male connector; 4-pin
Housing depth21.5 mm
Voltage drop 1.5 V DC
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Diagnostic Coverage (DC)0 %
Operating voltage10 ... 30 V DC
Control elementsSensing range adjuster
Response time0.5 ms
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
LED risk group labellingexempt group
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Transfer rateCOM 2 (38.4 kBaud)
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F) , fixed cable
-25 ... 60 В°C (-13 ... 140 В°F) , movable cable not appropriate for conveyor chains
SIO mode supportyes
Function indicatorLED yellow:
constantly on - object detected
constantly off - object not detected
Protection classIII
Detection range min.20 ... 50 mm
Product standardEN 60947-5-2
Housing width11 mm
Switching voltagemax. 30 V DC
Switching typeThe switching type of the sensor is adjustable. The default setting is:
C/Q - Pin4: NPN normally open / light-on, PNP normally closed / dark-on, IO-Link
/Q - Pin2: NPN normally closed / dark-on, PNP normally open / light-on
Control elementsLight-on/dark-on changeover switch
IO-Link Revision1.1
Communication interfaceIEC 61131-9
MTTFd724 a
Switching frequency1000 Hz
Degree of protectionIP67 / IP69 / IP69K
Compatible master port typeA
Device ID0x110101 (1114369)
Mission Time (TM)20 a

Comments

No comments yet

Write a comment