Pepperl+Fuchs OBE10M-R103-S2EP-IO-V31
Thru-beam sensor

- Miniature design with versatile mounting options
- IO-link interface for service and process data
- Various frequencies for avoiding mutual interference (cross-talk immunity)
- Extended temperature range
-40В°C ... 60В°C - High degree of protection IP69K

Item Number:
OBE10M-R103-S2EP-IO-V31
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
The switching type of the detector is adjustable. The default setting is:
C/Q - Pin 4: NPN normally open / off, PNP normally closed / on, IO-Link
/Q - Pin 2: NPN normally closed / on, PNP normally open / off
Diameter of the light spot | approx. 65 mm at a distance of 1 m |
Usage category | DC-12 and DC-13 |
Operating voltage | 10 ... 30 V DC |
Control elements | Receiver: light/dark switch |
Light source | LED |
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Receiver | OBE10M-R103-2EP-IO-V31 |
IO-Link Revision | 1.1 |
Interface type | IO-Link ( via C/Q = pin 4 ) |
Connection | M8 x 1 connector, 4-pin |
Degree of protection | IP67 / IP69 / IP69K |
Compatible master port type | A |
Threshold detection range | 12.5 m |
Housing depth | 26.7 mm |
Effective detection range | 0 ... 10 m |
Light type | modulated visible red light |
Function indicator | Yellow LED: Permanently lit - light path clear Permanently off - object detected Flashing (4 Hz) - insufficient operating reserve |
Process data witdh | Emitter: Process data output: 2 Bit Receiver: Process data input: 2 Bit Process data output: 2 Bit |
Switching type | The switching type of the sensor is adjustable. The default setting is: C/Q - Pin4: NPN normally open / dark-on, PNP normally closed / light-on, IO-Link /Q - Pin2: NPN normally closed / light-on, PNP normally open / dark-on |
MTTFd | 462 a |
LED risk group labelling | exempt group |
Housing height | 43.9 mm |
Emitter | OBE10M-R103-S-IO-V31 |
Housing width | 15 mm |
Min. cycle time | 2.3 ms |
Diagnostic Coverage (DC) | 0 % |
Angle of divergence | 3.7 В° |
Mission Time (TM) | 20 a |