Pepperl+Fuchs OBT300-R101-IO-1T-L-Y0112 Triangulation sensor (BGE)

Pepperl+Fuchs OBT300-R101-IO-1T-L-Y0112
Item Number: OBT300-R101-IO-1T-L-Y0112
  • Miniature design with versatile mounting options
  • Secure and gapless detection, even near the surface through background evaluation
  • DuraBeam Laser Sensors - durable and employable like an LED
  • Extended temperature range
    -40В°C ... 60В°C
  • High degree of protection IP69K
  • IO-link interface for service and process data
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Detection range7 ... 300 mm
FDA approvalIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Switching typeThe switching type of the sensor is adjustable. The default setting is:
C/Q - Pin4: NPN normally open / dark-on, PNP normally closed / light-on, IO-Link
/Q - Pin2: NPN normally closed / light-on, PNP normally open / dark-on
Min. cycle time2.3 ms
Control elementsLight-on/dark-on changeover switch
Diameter of the light spotapprox. 1 mm at a distance of 200 mm
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Function indicatorLED yellow:
constantly on - background detected (object not detected)
constantly off - object detected
Degree of protectionIP67 / IP69 / IP69K
Light sourcelaser diode
IO-Link Revision1.1
Interface typeIO-Link ( via C/Q = pin 4 )
Light typemodulated visible red light
Usage categoryDC-12 and DC-13
Operating voltage10 ... 30 V DC
Process data witdhProcess data input 1 Bit
Process data output 2 Bit
Compatible master port typeA
Diagnostic Coverage (DC)0 %
Black/White difference (6 %/90 %)< 5 % at 150 mm
Connectionfixed cable 300 mm with M8 x 1 male connector; 4-pin
MTTFd560 a
Angle of divergenceapprox. 0.3 В°
Mission Time (TM)20 a

Comments

No comments yet

Write a comment

captcha
in international format without spaces
All fields are required