Pepperl+Fuchs OBT80-R103-2EP-IO-L Triangulation sensor (BGS)

Pepperl+Fuchs OBT80-R103-2EP-IO-L
Item Number: OBT80-R103-2EP-IO-L
  • Miniature design with versatile mounting options
  • Best background suppressor in its class
  • Precision object detection, almost irrespective of the color
  • Extended temperature range
    -40В°C ... 60В°C
  • High degree of protection IP69K
  • IO-link interface for service and process data
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Black/White difference (6 %/90 %)< 5 % at 60 mm
Function indicatorLED yellow:
constantly on - object detected
constantly off - object not detected
Massapprox. 38 g
SIO mode supportyes
Angle of divergenceapprox. 0.3 В°
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Device ID0x110606 (1115654)
Switching frequency1650 Hz
Reference targetstandard white, 100 mm x 100 mm
Ambient light limitEN 60947-5-2 : 40000 Lux
Interface typeIO-Link ( via C/Q = BK )
MTTFd560 a
Communication interfaceIEC 61131-9
Housing height36.5 mm
Housing depth26.7 mm
Detection range max.7 ... 80 mm
Adjustment range25 ... 80 mm
Switching voltagemax. 30 V DC
Detection range7 ... 80 mm
Protection classIII
Light sourcelaser diode
Device profileSmart Sensor
Compatible master port typeA
Switching currentmax. 100 mA , resistive load
Usage categoryDC-12 and DC-13
Housing width15 mm
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Cable length2 m
No-load supply current< 20 mA at 24 V supply voltage
Process data witdhProcess data input 1 Bit
Process data output 2 Bit
Min. cycle time2.3 ms
Laser safetyEN 60825-1:2014
Control elementsSensing range adjuster
Connection2 m fixed cable
Switching typeThe switching type of the sensor is adjustable. The default setting is:
C/Q - BK: NPN normally open / light-on, PNP normally closed / dark-on, IO-Link
/Q - WH: NPN normally closed / dark-on, PNP normally open / light-on
Response time300 micro/s
Control elementsLight-on/dark-on changeover switch
Transfer rateCOM 2 (38.4 kBaud)
FDA approvalIEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Operating voltage10 ... 30 V DC
Product standardEN 60947-5-2
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F) , fixed cable
-25 ... 60 В°C (-13 ... 140 В°F) , movable cable not appropriate for conveyor chains
Light typemodulated visible red light
Diagnostic Coverage (DC)0 %
Diameter of the light spotapprox. 1 mm at a distance of 60 mm
IO-Link Revision1.1
Ripplemax. 10 %
Detection range min.5 ... 25 mm
Mission Time (TM)20 a
Voltage drop 1.5 V DC
Degree of protectionIP67 / IP69 / IP69K

Comments

No comments yet

Write a comment

captcha
in international format without spaces
All fields are required