Pepperl+Fuchs OCS2000-M1K-N2
Retroreflective sensor

We ship to United States of America!
  • ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas)
  • Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 ?°C Da
  • Glare protected with polarization filter
  • Adjustable sensor head
  • Scratch resistant mineral glass lens
Item Number: OCS2000-M1K-N2
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

The OCS2000-M1K-N2 is a high-precision optical sensor designed for mid-range detection up to 2000 mm. Compact in design, this sensor easily integrates into tight spaces within industrial setups. Its robust construction ensures durability in demanding settings, making it an ideal choice for material positioning, level measurement, and quality control processes in manufacturing. The OCS2000-M1K-N2 offers reliable performance, even in environments with dust and moisture.

Datasheet:

ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb
Effective internal capacitance Cimax. 1200 nF
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated.
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated.
Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Switching voltage8 V DC (Ri approx. 1 kΩ)
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Mass100 g
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
EC-Type Examination CertificatePTB 01 ATEX 2203 X
StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006
ATEX markingZone 20/21: II 1D Ex ia IIIC T 135?°C Da
IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb
Response time5 ms
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Effective detection range0 ... 2 m
Reflector distance100 ... 2000 mm
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Certificate numberIECEx PTB 12.0060 X
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Polarization filteryes
Operating voltage6 ... 20 V DC (Ri approx. 0 Ohm)
Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Effective internal inductance Linegligibly small
Function indicatorLED yellow: switching state
EC-Type Examination CertificateZELM 03 ATEX 0196 X
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
StandardsEN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Degree of protectionIP67 according to EN 60529, Class II insulation
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
Housing height30 mm
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Product standardEN 60947-5-2
CE markingCE0102
Housing width30 mm
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Light sourceLED , 660 nm
StandardsIEC 60079-0:2011 IEC 60079-11:2011
Reference targetRetro-reflector C110-2
ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
Storage temperature-40 ... 80 ?°C (-40 ... 176 ?°F)
Threshold detection range2 m
Directive conformity2014/34/EU
MTTFd1319 a
Effective internal inductance Linegligibly small
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Effective internal capacitance Cimax. 75 nF
Mission Time (TM)20 a
Ripple5 %
Certificate numberIECEx ZLM 12.0005X
Diagnostic Coverage (DC)0 %
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
Housing depth102 mm
Light typemodulated visible red light
Signal output1 NAMUR output NC/NO programmable
Switching frequency≤ 100 Hz
Effective internal capacitance Cimax. 75 nF
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
CCC approvalCCC approval / marking not required for products rated ≤36 V
StandardsEN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
Time delay before availability20 ms
Effective internal inductance Linegligibly small
Switching typelight/dark on, programmable
Directive conformity2014/34/EU
Ambient light limit≤ 10000 Lux sun light
≤ 7500 Lux halogen light
Effective internal capacitance Cimax. 1200 nF
Effective internal inductance Linegligibly small
IECEx markingEx ia IIIC T135?°C Da
CE markingCE0102
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.

Buy Pepperl+Fuchs OCS2000-M1K-N2 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. delivers top-quality industrial control products. Our extensive inventory ensures you find the parts you need, with worldwide delivery options. We offer competitive prices and personalized service. Get in touch today to see how we can support your business effectively and efficiently.

Comments

No comments yet

Write a comment