Pepperl+Fuchs OCT300-M1K-N2
Diffuse mode sensor

Pepperl+Fuchs OCT300-M1K-N2
We ship to United States of America!
  • ATEX-, IECEX approval for zone 20 (Dust) and zone 1 (Gas)
  • Intrinsically safe, Ex op is ia IIC T6 Gb/IIIC T 135 ?°C Da
  • Adjustable sensor head
  • Scratch resistant mineral glass lens
Item Number: OCT300-M1K-N2
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +

The OCT300-M1K-N2 is an optical distance sensor engineered for precise measurements over short distances. With a range of up to 300 mm, this sensor is ideal for applications that require pinpoint accuracy, such as thickness measurement or part positioning. The OCT300’s compact form factor and mounting flexibility make it easy to install in various automation setups, while its robust build ensures reliable performance even in harsh environments.

Datasheet:

ConnectionM16 terminal compartment, core cross section ≤ 2.5 mm2
Housing height30 mm
Product standardEN 60947-5-2
Ambient light limit≤ 40000 Lux sun light
≤ 30000 Lux halogen light
Effective internal inductance Linegligibly small
MTTFd1319 a
StandardsEN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated.
CE markingCE0102
Switching frequency≤ 100 Hz
Effective internal capacitance Cimax. 75 nF
Effective internal capacitance Cimax. 75 nF
Storage temperature-40 ... 80 ?°C (-40 ... 176 ?°F)
Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Mission Time (TM)20 a
Signal output1 NAMUR output NC/NO programmable
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Diagnostic Coverage (DC)0 %
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Effective internal inductance Linegligibly small
CE markingCE0102
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Detection range0 ... 300 mm
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. This certificate does not guarantee that the components installed in the partition isolate the zones completely from one another. Appropriate measures must be taken when the partition is set up to ensure the zones are completely isolated.
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Switching voltage8 V DC (Ri approx. 1 kΩ)
Light sourceIRED , 880 nm
IECEx markingEx ia IIIC T135?°C Da
Switching typelight/dark on, programmable
Effective internal capacitance Cimax. 1200 nF
Control elementsSensing range adjuster
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
MaintenanceNo modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Effective internal capacitance Cimax. 1200 nF
Effective internal inductance Linegligibly small
EC-Type Examination CertificateZELM 03 ATEX 0196 X
Directive conformity2014/34/EU
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
ATEX markingZone 20/21: II 1D Ex ia IIIC T 135?°C Da
Adjustment range70 ... 300 mm
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Time delay before availability20 ms
ATEX markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb
Temperature influence≤ 0.5 mm/K
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
StandardsIEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006
Installation, commissioningThe associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
Effective internal inductance Linegligibly small
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Operating voltage6 ... 20 V DC (Ri approx. 0 Ohm)
Ambient temperatureThe temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
ApplicantPepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
Housing width30 mm
Light typemodulated infrared light
Repeat accuracy≤ 0.5 % of the sensing range
Mass100 g
Ripple5 %
StandardsEN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
Reference targetstandard white 200 mm x 200 mm
GeneralThe apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
IECEx markingZone 1: II 2G Ex ia op is IIC T6...T1 Gb
Certificate numberIECEx PTB 12.0060 X
Housing depth102 mm
EC-Type Examination CertificatePTB 01 ATEX 2203 X
Function indicatorLED yellow: switching state
StandardsIEC 60079-0:2011 IEC 60079-11:2011
Certificate numberIECEx ZLM 12.0005X
Response time5 ms
Degree of protectionIP67
Directive conformity2014/34/EU

Buy Pepperl+Fuchs OCT300-M1K-N2 with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. offers comprehensive industrial automation solutions. With a wide selection of products and express delivery options, we meet your demands efficiently. Our commitment to quality and customer satisfaction sets us apart. Experience the difference with our reliable services.

Comments

No comments yet

Write a comment