Pepperl+Fuchs OQT120-R103-2EP-IO Triangulation sensor (SbR)

Pepperl+Fuchs OQT120-R103-2EP-IO
Item Number: OQT120-R103-2EP-IO
  • Miniature design with versatile mounting options
  • Multi Pixel Technology (MPT) - flexibility and adaptability
  • Reduction of device variety - several switch points within one sensor
  • Reliable detection of all surfaces, independent of color and structure
  • Low sensitivity to target color
  • IO-link interface for service and process data
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Switching voltagemax. 30 V DC
Interface typeIO-Link ( via C/Q = BK )
Degree of protectionIP67 / IP69 / IP69K
Connection2 m fixed cable
Ripplemax. 10 %
Communication interfaceIEC 61131-9
Transfer rateCOM 2 (38.4 kBaud)
No-load supply current< 25 mA at 24 V supply voltage
Light sourceLED
Response time2.3 ms
Diameter of the light spotapprox. 8 mm at a distance of 120 mm
Control elements5-step rotary switch for operating modes selection
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F) , fixed cable
-25 ... 60 В°C (-13 ... 140 В°F) , movable cable not appropriate for conveyor chains
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Switching frequency217 Hz
Device ID0x110803 (1116163)
Ambient light limitEN 60947-5-2 : 30000 Lux
Process data witdhProcess data input 2 Bit
Process data output 2 Bit
Massapprox. 38 g
Detection range min.5 ... 20 mm
Housing height36.5 mm
Usage categoryDC-12 and DC-13
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
MTTFd600 a
Light typemodulated visible red light
Housing width15 mm
Min. cycle time2.3 ms
SIO mode supportyes
Black/White difference (6 %/90 %)< 5 % at 120 mm
Detection range5 ... 120 mm
Angle of divergenceapprox. 4 В°
Diagnostic Coverage (DC)0 %
Device profileSmart Sensor
Product standardEN 60947-5-2
LED risk group labellingexempt group
Cable length2 m
Voltage drop 1.5 V DC
Switching currentmax. 100 mA , resistive load
Adjustment range20 ... 120 mm
Control elementsTeach-In key
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Mission Time (TM)20 a
Housing depth26.7 mm
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Switching typeThe default setting is:
C/Q - BK: NPN normally open, PNP normally closed, IO-Link
Q2 - WH: NPN normally open, PNP normally closed
Reference targetstandard white, 100 mm x 100 mm
IO-Link Revision1.1
Compatible master port typeA
Detection range max.5 ... 120 mm
Protection classIII
Operating voltage10 ... 30 V DC
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)

Comments

No comments yet

Write a comment

captcha
in international format without spaces
All fields are required