Pepperl+Fuchs OQT120-R103-2EP-IO-0,3M-V1 Triangulation sensor (SbR)

Pepperl+Fuchs OQT120-R103-2EP-IO-0,3M-V1
Item Number: OQT120-R103-2EP-IO-0,3M-V1
  • Miniature design with versatile mounting options
  • Multi Pixel Technology (MPT) - flexibility and adaptability
  • Reduction of device variety - several switch points within one sensor
  • Reliable detection of all surfaces, independent of color and structure
  • Low sensitivity to target color
  • IO-link interface for service and process data
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
No-load supply current< 25 mA at 24 V supply voltage
Housing depth26.7 mm
IO-Link Revision1.1
Compatible master port typeA
Detection range5 ... 120 mm
Housing height36.5 mm
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Protection classIII
SIO mode supportyes
Angle of divergenceapprox. 4 В°
Reference targetstandard white, 100 mm x 100 mm
Detection range max.5 ... 120 mm
Connection300 mm fixed cable with M12 x 1, 4-pin connector
Switching frequency217 Hz
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
LED risk group labellingexempt group
Diameter of the light spotapprox. 8 mm at a distance of 120 mm
Voltage drop 1.5 V DC
Process data witdhProcess data input 2 Bit
Process data output 2 Bit
Min. cycle time2.3 ms
Product standardEN 60947-5-2
Ambient light limitEN 60947-5-2 : 30000 Lux
Device ID0x110803 (1116163)
Control elements5-step rotary switch for operating modes selection
Housing width15 mm
Light sourceLED
Transfer rateCOM 2 (38.4 kBaud)
Degree of protectionIP67 / IP69 / IP69K
Switching currentmax. 100 mA , resistive load
MTTFd600 a
Response time2.3 ms
Diagnostic Coverage (DC)0 %
Control elementsTeach-In key
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F) , fixed cable
-25 ... 60 В°C (-13 ... 140 В°F) , movable cable not appropriate for conveyor chains
Black/White difference (6 %/90 %)< 5 % at 120 mm
Mission Time (TM)20 a
Operating voltage10 ... 30 V DC
Adjustment range20 ... 120 mm
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Communication interfaceIEC 61131-9
Light typemodulated visible red light
Massapprox. 23 g
Interface typeIO-Link ( via C/Q = pin 4 )
Usage categoryDC-12 and DC-13
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Device profileSmart Sensor
Detection range min.5 ... 20 mm
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Switching voltagemax. 30 V DC
Cable length0.3 m
Ripplemax. 10 %
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
Q2 - Pin2: NPN normally open, PNP normally closed

Comments

No comments yet

Write a comment

captcha
in international format without spaces
All fields are required