Pepperl+Fuchs OQT150-R101-2EP-IO-L
Triangulation sensor (SbR)
- Miniature design with versatile mounting options
- Multi Pixel Technology (MPT) - flexibility and adaptability
- Reduction of device variety - several switch points within one sensor
- DuraBeam Laser Sensors - durable and employable like an LED
- Reliable detection of all surfaces, independent of color and structure
- IO-link interface for service and process data
Item Number:
OQT150-R101-2EP-IO-L
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Detection range | 8 ... 150 mm |
Diameter of the light spot | approx. 2 mm at a distance of 150 mm |
Switching voltage | max. 30 V DC |
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Usage category | DC-12 and DC-13 |
Light type | modulated visible red light |
Response time | 2.3 ms |
Housing width | 13.9 mm |
MTTFd | 560 a |
Protection class | III |
SIO mode support | yes |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
IO-Link Revision | 1.1 |
Transfer rate | COM 2 (38.4 kBaud) |
Ripple | max. 10 % |
FDA approval | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 |
Adjustment range | 20 ... 150 mm |
Light source | laser diode |
Min. cycle time | 2.3 ms |
Ambient light limit | EN 60947-5-2 : 30000 Lux |
Storage temperature | -40 ... 70 В°C (-40 ... 158 В°F) |
Process data witdh | Process data input 2 Bit Process data output 2 Bit |
Product standard | EN 60947-5-2 |
Connection | 2 m fixed cable |
Compatible master port type | A |
Laser safety | EN 60825-1:2014 |
Switching type | The default setting is: C/Q - BK: NPN normally open, PNP normally closed, IO-Link Q2 - WH: NPN normally open, PNP normally closed |
Ambient temperature | -40 ... 60 В°C (-40 ... 140 В°F) , fixed cable -25 ... 60 В°C (-13 ... 140 В°F) , movable cable not appropriate for conveyor chains |
Switching frequency | 217 Hz |
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
Mission Time (TM) | 20 a |
Switching current | max. 100 mA , resistive load |
Communication interface | IEC 61131-9 |
Reference target | standard white, 100 mm x 100 mm |
Device ID | 0x110802 (1116162) |
Device profile | Smart Sensor |
Housing height | 33.8 mm |
Cable length | 2 m |
Operating voltage | 10 ... 30 V DC |
Voltage drop | 1.5 V DC |
Detection range max. | 8 ... 150 mm |
Degree of protection | IP67 / IP69 / IP69K |
Black/White difference (6 %/90 %) | < 3 % at 150 mm |
Angle of divergence | approx. 1 В° |
Interface type | IO-Link ( via C/Q = BK ) |
Diagnostic Coverage (DC) | 0 % |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
Mass | approx. 36 g |
Control elements | Teach-In key |
No-load supply current | < 20 mA at 24 V supply voltage |
Housing depth | 18.3 mm |
Control elements | 5-step rotary switch for operating modes selection |
Detection range min. | 8 ... 20 mm |
People also buy
Comments
No comments yet