Pepperl+Fuchs OQT400-R200-EP-IO-0,3M-V3 Triangulation sensor (SbR)

Pepperl+Fuchs OQT400-R200-EP-IO-0,3M-V3
Item Number: OQT400-R200-EP-IO-0,3M-V3
  • Medium design with versatile mounting options
  • Multi Pixel Technology (MPT) - flexibility and adaptability
  • Reduction of device variety - several switch points within one sensor
  • Reliable detection of all surfaces, independent of color and structure
  • Low sensitivity to target color
  • IO-link interface for service and process data
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
LED risk group labellingexempt group
Light typemodulated visible red light
Ambient light limitEN 60947-5-2 : 70000 Lux
Usage categoryDC-12 and DC-13
Housing depth41.7 mm
Angle of divergenceapprox. 2.5 В°
Reference targetstandard white, 100 mm x 100 mm
Response time2.3 ms
Connection300 mm fixed cable with M8 x 1, 3-pin connector
Black/White difference (6 %/90 %)< 5 %
CCC approvalCCC approval / marking not required for products rated 36 V
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Signal output1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, overvoltage protected
MTTFd600 a
Massapprox. 41 g
No-load supply current< 25 mA at 24 V supply voltage
Detection range max.40 ... 400 mm
Detection range40 ... 400 mm
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Communication interfaceIEC 61131-9
Min. cycle time2.3 ms
Mission Time (TM)20 a
Interface typeIO-Link ( via C/Q = pin 4 )
Switching currentmax. 100 mA , resistive load
Operating voltage10 ... 30 V DC
Adjustment range100 ... 400 mm
Transfer rateCOM 2 (38.4 kBaud)
Voltage drop 1.5 V DC
Housing height50.6 mm
Housing width15 mm
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F) , fixed cable
-20 ... 60 В°C (-4 ... 140 В°F) , movable cable not appropriate for conveyor chains
Protection classIII
Compatible master port typeA
Control elements5-step rotary switch for operating modes selection
Diagnostic Coverage (DC)0 %
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
Product standardEN 60947-5-2
SIO mode supportyes
Process data witdhProcess data input 2 Bit
Process data output 2 Bit
Cable length0.3 m
Device ID0x111801 (1120257)
Light sourceLED
Detection range min.40 ... 100 mm
Control elementsTeach-In key
IO-Link Revision1.1
Switching voltagemax. 30 V DC
Diameter of the light spotapprox. 15 mm at a distance of 400 mm
Ripplemax. 10 %
Device profileIdentification and diagnosis
Smart Sensor type 0
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Degree of protectionIP67 / IP69 / IP69K
Switching frequency217 Hz

Comments

No comments yet

Write a comment

captcha
in international format without spaces