Pepperl+Fuchs OQT400-R201-2EP-IO Triangulation sensor (SbR)


Item Number: OQT400-R201-2EP-IO
- Medium design with versatile mounting options
- Multi Pixel Technology (MPT) - flexibility and adaptability
- Reduction of device variety - several switch points within one sensor
- Reliable detection of all surfaces, independent of color and structure
- Low sensitivity to target color
- IO-link interface for service and process data
- Overview
- Datasheet
- Alternative numbers
- Comments
Adjustment range | 100 ... 400 mm |
Switching frequency | 217 Hz |
Communication interface | IEC 61131-9 |
Protection class | III |
Detection range min. | 40 ... 100 mm |
Reference target | standard white, 100 mm x 100 mm |
Interface type | IO-Link ( via C/Q = BK ) |
Compatible master port type | A |
Min. cycle time | 2.3 ms |
Diagnostic Coverage (DC) | 0 % |
Detection range | 40 ... 400 mm |
MTTFd | 600 a |
Device profile | Identification and diagnosis Smart Sensor type 0 |
Ripple | max. 10 % |
LED risk group labelling | exempt group |
Housing depth | 41.7 mm |
Transfer rate | COM 2 (38.4 kBaud) |
Diameter of the light spot | approx. 15 mm at a distance of 400 mm |
Operating voltage | 10 ... 30 V DC |
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Ambient light limit | EN 60947-5-2 : 70000 Lux |
Usage category | DC-12 and DC-13 |
Connection | 2 m fixed cable |
Mass | approx. 83 g |
SIO mode support | yes |
Ambient temperature | -40 ... 60 В°C (-40 ... 140 В°F) , fixed cable -20 ... 60 В°C (-4 ... 140 В°F) , movable cable not appropriate for conveyor chains |
IO-Link Revision | 1.1 |
Control elements | 5-step rotary switch for operating modes selection |
Voltage drop | 1.5 V DC |
Mission Time (TM) | 20 a |
Response time | 2.3 ms |
Control elements | Teach-In key |
Product standard | EN 60947-5-2 |
Light type | modulated visible red light |
Switching current | max. 100 mA , resistive load |
Cable length | 2 m |
Storage temperature | -40 ... 70 В°C (-40 ... 158 В°F) |
Angle of divergence | approx. 2.5 В° |
Detection range max. | 40 ... 400 mm |
Housing width | 15 mm |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
CCC approval | CCC approval / marking not required for products rated 36 V |
Light source | LED |
Housing height | 61.7 mm |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
Black/White difference (6 %/90 %) | < 5 % |
No-load supply current | < 25 mA at 24 V supply voltage |
Device ID | 0x111811 (1120273) |
Switching voltage | max. 30 V DC |
Switching type | The default setting is: C/Q - BK: NPN normally open, PNP normally closed, IO-Link Q2 - WH: NPN normally open, PNP normally closed |
Process data witdh | Process data input 2 Bit Process data output 2 Bit |
Degree of protection | IP67 / IP69 / IP69K |