Pepperl+Fuchs PCV100-F200-B17-V1D-6011 Optical reading head


Item Number: PCV100-F200-B17-V1D-6011
- Non-contact positioning on Data Matrix code tape
- Mechanically rugged: no wearing parts, long operating life, maintenance-free
- High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
- Travel ranges up to 10 km, in X and Y direction
- PROFINET interface
- Integrated switch
- Overview
- Datasheet
- Alternative numbers
- Comments
No-load supply current | max. 400 mA |
Storage temperature | -20 ... 85 В°C (-4 ... 185 В°F) |
LED indication | 7 LEDs (communication, alignment aid, status information) |
Reading field | 60 mm x 35 mm |
MTTFd | 103 a |
Housing depth | 50 mm |
Connection type | 8-pin, M12x1 connector, standard (supply+IO) 4-pin, M12x1 socket, D-coded (LAN) 4-pin, M12x1 socket, D-coded (LAN) |
CCC approval | CCC approval / marking not required for products rated 36 V |
Relative humidity | 90 % , noncondensing |
Degree of protection | IP67 |
Transfer rate | 100 MBit/s |
Housing width | 70 mm |
Mission Time (TM) | 51 a |
Switching voltage | Operating voltage |
Noise immunity | EN 61000-6-2:2005 |
Measuring range | max. 10000 m |
Ambient light limit | 100000 Lux |
Light type | Integrated LED lightning (red) |
Housing height | 70 mm |
Interface type | USB Service |
Depth of focus | В± 40 mm |
Shock resistance | EN 60068-2-27:2009 |
UL approval | cULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure |
Output type | 1 to 3 switch outputs , programmable , short-circuit protected |
Interface type | 100 BASE-TX |
Switching current | 150 mA each output |
Passage speed | 6 m/s |
Operating temperature | 0 ... 60 В°C (32 ... 140 В°F) , -20 ... 60 В°C (-4 ... 140 В°F) (noncondensing; prevent icing on the lens!) |
Operating voltage | 15 ... 30 V DC , PELV |
Diagnostic Coverage (DC) | 0 % |
Mass | approx. 200 g |
Emitted interference | EN 61000-6-4:2007+A1:2011 |
Input impedance | 27 kandOmega; |
Resolution | В± 0.1 mm |
Vibration resistance | EN 60068-2-6:2008 |
Read distance | 100 mm |
Protocol | PROFINET IO Real-Time (RT) Conformance class A |
Power consumption | 6 W |
Input type | 1 funtion input 0-level: -UBor unwired 1-level: +8 V ... +UB , programmable |