Pepperl+Fuchs PCV100-F200-R4-V19 Optical reading head

Pepperl+Fuchs PCV100-F200-R4-V19
Item Number: PCV100-F200-R4-V19
  • RS 485 interface
  • Non-contact positioning on Data Matrix code tape
  • Travel ranges up to 10 km, in X and Y direction
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Read distance100 mm
Power consumption3 W
Input type1 to 3 functional inputs , programmable
CCC approvalCCC approval / marking not required for products rated 36 V
Relative humidity90 % , noncondensing
MTTFd100 a
Connection type8-pin, M12 x 1 connector
Switching voltageOperating voltage
Data output codebinary code
Operating temperature0 ... 60 В°C (32 ... 140 В°F) , -20 ... 60 В°C (-4 ... 140 В°F) (noncondensing; prevent icing on the lens!)
Input impedance 27 kandOmega;
Housing height70 mm
EAC conformityTR CU 020/2011
Output type1 to 3 switch outputs , PNP , programmable , short-circuit protected
Storage temperature-20 ... 85 В°C (-4 ... 185 В°F)
Housing width70 mm
Shock resistanceEN 60068-2-27:2009
Massapprox. 160 g
UL approvalcULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure
LED indicator7 LEDs (communication, alignment aid, status information)
TerminationSwitchable terminal resistor
Degree of protectionIP67
ResolutionВ± 0.1 mm
Noise immunityEN 61000-6-2:2005
Operating voltage15 ... 30 V DC , PELV
Light typeIntegrated LED lightning (red)
Vibration resistanceEN 60068-2-6:2008
Transfer rate38400 ... 230400 Bit/s
Switching current150 mA each output
Interface typeRS 485 interface
Reading field50 mm x 30 mm
Passage speed 8 m/s
Diagnostic Coverage (DC)0 %
Measuring rangemax. 10000 m
Emitted interferenceEN 61000-6-4:2007+A1:2011
No-load supply currentmax. 200 mA
Mission Time (TM)50 a

Comments

No comments yet

Write a comment

captcha
in international format without spaces
All fields are required