Pepperl+Fuchs PMI360D-F130-IE8-V15
Ind. angular measuring system
- Measuring range 0 ... 360В°
- Analog output 4 mA ... 20 mA
- Adjustable switch points
Item Number:
PMI360D-F130-IE8-V15
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Mission Time (TM) | 20 a |
Temperature drift | 0.02 В° / В°C (-25 В°C ... 70 В°C) |
Resolution | 0.4В° |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
CCC approval | CCC approval / marking not required for products rated 36 V |
Storage temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Operating current | 100 mA |
Installation | non-flush |
Connection type | 5-pin, M12 x 1 connector |
Repeat accuracy | В± 0.25 В° |
Housing material | PBT |
Reverse polarity protection | reverse polarity protected |
MTTFd | 265 a |
Rotational speed | max. 100 min-1 |
Shaft diameter | max. 27.5 mm Steel |
Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
Measurement range | 360В° |
Operating voltage indicator | LED green |
Operating voltage | 18 ... 30 V |
No-load supply current | 45 mA |
Load resistor | 400 andOmega; |
Short-circuit protection | pulsing |
Linearity error | В± 0.6 В° , (with original actuator) |
Mass | 180 g |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Voltage drop | 3 V |
Diagnostic Coverage (DC) | 0 % |
Output type | 1 current output: 4 ... 20 mA |
Degree of protection | IP67 |
People also buy