Pepperl+Fuchs PMI80-F90-IU-IO-V15 Inductive positioning system


Item Number: PMI80-F90-IU-IO-V15
- Parameterization and diagnosis via IO-Link
- Measuring range 0 ... 80 mm
- Parameterisable measuring range
- Analog current or voltage output, programmable
- Overview
- Datasheet
- Alternative numbers
- Comments
Measurement range | 0 ... 80 mm |
No-load supply current | 40 mA |
Repeat accuracy | В± 0.1 mm |
Mass | 83 g |
Linearity range | 1 ... 79 mm |
Mission Time (TM) | 20 a |
Object distance | 0.5 ... 3 mm , recommended: 1.5 mm |
MTTFd | 311 a |
Degree of protection | IP67 / IP69K |
LED STATUS | Status display LED, green/red (Power on, communication/error, missing damping element) |
SIO mode support | yes |
Compatible master port type | A |
Resolution | 50 andmicro;m |
Device profile | Smart Sensor |
LED S3 | Damping element in the configured analog measuring range |
Device ID | 0x200301 (2097921) |
Interface type | IO-Link (via C/Q = Pin 4) |
Operating voltage indicator | LED green |
Short-circuit protection | voltage output: current limit |
IO-Link Revision | 1.1 |
Value range | 0000h ... 6400h |
Output type | current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmable |
Switching element function | Analog current or voltage output, programmable |
Process data witdh | Process data input: 16 Bit Process data output: none |
Temperature drift | В± 0.5 mm (-25 В°C ... 70 В°C) |
Diagnostic Coverage (DC) | 0 % |
Linearity error | within measuring range: В± 0.8 mm within linearity range: В± 0.4 mm |
Reverse polarity protection | reverse polarity protected |
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure |
Ambient temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Operating voltage | 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) |
Transfer rate | COM 2 (38.4 kBaud) |
Connection type | 5-pin, M12 x 1 connector |
Load resistor | current output: 400 andOmega; voltage output: 1000 andOmega; |
Min. cycle time | 2.3 ms |
People also buy
Comments