Pepperl+Fuchs PMI80-F90-IU-V1
Inductive positioning system

Pepperl+Fuchs PMI80-F90-IU-V1
  • Analog output 0 V ... 10 V/4 mA ... 20 mA
  • Measuring range 0 ... 80 mm
Item Number: PMI80-F90-IU-V1
304.03
-
+
Total price: 304.03
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Operating voltage18 ... 30 V DC
Measurement range0 ... 80 mm
Repeat accuracyВ± 0.1 mm
Linearity range1 ... 79 mm
Diagnostic Coverage (DC)0 %
Operating voltage indicatorLED green
Linearity errorwithin measuring range: В± 0.8 mm
within linearity range: В± 0.4 mm
Temperature driftВ± 0.5 mm (-25 В°C ... 70 В°C)
No-load supply current 40 mA
Degree of protectionIP67
Short-circuit protectionvoltage output: pulsing
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Resolution125 andmicro;m
Output type1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V
Switching element functionanalog, current or voltage output
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Connection type4-pin, M12 x 1 connector
MTTFd419 a
CCC approvalCCC approval / marking not required for products rated 36 V
Reverse polarity protectionreverse polarity protected
Load resistorcurrent output: 400 andOmega;
voltage output: 1000 andOmega;
Object distance0.5 ... 3 mm , recommended: 2 mm
Mission Time (TM)20 a

Comments

No comments yet

Write a comment