Pepperl+Fuchs PMI90DV-F130-I2E2-V15
Ind. angular measuring system
- Analog position indicator with end position monitoring
- 2 configurable switching frames
- Preset range of angle measurement 0 ... 90В°
- Extended analog signal range
- Overview
- Comments
Linearity error | В± 1.5 В° , (with original actuator) |
Output type | current output 3.8 ... 20.5 mA (RL < 400 andOmega;) |
Degree of protection | IP67 |
Adjustment range | 180В° , 2 switch frames programmable |
Measurement range | max. 180В° min. 90В° |
LED yellow 1 | switching state, Switching output 1 |
Switching hysteresis | 1 В° |
No-load supply current | 45 mA |
Internal measurement cycle | 30 ms |
Mass | 180 g |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Operating current | 100 mA |
Short-circuit protection | pulsing |
CCC approval | CCC approval / marking not required for products rated 36 V |
Connection type | 5-pin, M12 x 1 connector |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
MTTFd | 234 a |
Operating voltage | 18 ... 30 V DC |
Temperature drift | 0.02 В° / В°C (-25 В°C ... 70 В°C) |
Repeat accuracy | В± 0.25 В° |
Resolution | 0.2 В° |
Diagnostic Coverage (DC) | 0 % |
Voltage drop | 3 V |
Reverse polarity protection | reverse polarity protected |
Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable |
LED yellow 2 | switching state, Switching output 2 |
LED PWR/ERR | Status display LED, green/red (Power on / missing actuator / keylock) |
Mission Time (TM) | 20 a |