Pepperl+Fuchs PXV100A-F200-B28-V1D-6011
Optical reader - safePXV
- SIL 3 (EN 61508)
- Category 4 PL e (EN ISO 13849)
- PROFINET interface
- PROFIsafe interface
- Safe, non-contact positioning on Data Matrix code tape
- Traverse distance up to 100 km
- Mechanically rugged: no wearing parts, long operating life, maintenance-free
Item Number:
PXV100A-F200-B28-V1D-6011
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Emitted interference | EN 61000-6-4:2007+A1:2011 |
Fieldbus standard | PROFIsafe in accordance with IEC 61784-3-3; profile 2.4 |
Passage speed | 8 m/s |
LED indication | 7 LEDs (communication, status messages) |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Relative humidity | 90 % , noncondensing |
CE conformity | CE |
TГњV approval | TГњV Rheinland 01/205/5669.00/18 |
Degree of protection | IP67 |
Power consumption | 6 W |
MTTF | 41.66 a |
Mission Time (TM) | 20 a |
Depth of focus | В± 40 mm |
Interface type | 100 BASE-TX |
Mass | approx. 200 g |
Ambient light limit | 30000 Lux |
Operating voltage | 20 ... 30 V DC , PELV |
Field of view | typ. 60 mm x 35 mm |
Light type | Integrated LED lightning (red/blue) |
Photobiological safety | risk group 2 according IEC 62471 |
Reaction time | 165 ms |
Operating temperature | 0 ... 45 В°C (32 ... 113 В°F) , -20 ... 45 В°C (-4 ... 113 В°F) (noncondensing; prevent icing on the lens!) |
Connection type | 8-pin, M12x1 connector, standard 4-pin, M12x1 socket, D-coded (LAN) 4-pin, M12x1 socket, D-coded (LAN) |
CCC approval | CCC approval / marking not required for products rated 36 V |
PFH | 1.09 E-8 typ. |
Functional safety | EN ISO 13849-1:2015 ; EN 61508:2010 part 1-7 ; EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
MTTFd | 104.74 a |
No-load supply current | max. 300 mA |
Housing height | 70 mm |
Housing width | 70 mm |
Category | Cat. 4 |
Transfer rate | 100 MBit/s |
Altitude | max. 2000 m above MSL |
Performance level (PL) | PL e |
Protocol | PROFINET IO Real-Time (RT) Conformance class B |
Read distance | 100 mm |
Shock resistance | EN 60068-2-27:2009 |
Safety Integrity Level (SIL) | SIL 3 |
Vibration resistance | EN 60068-2-6:2008 |
Measuring range | max. 100000 m |
Noise immunity | EN 61000-6-7:2015 |
Housing depth | 50 mm |
People also buy
Comments
No comments yet