Pepperl+Fuchs R4D0-FB-IA*
FieldBarrierВ® for Cabinet Installation
- 8 ... 12 outputs Ex ia IIC, FISCO and Entity
- Advanced fault isolation and diagnostics at the spur
- FieldBarrier in Zone 1/Div. 2
- Instruments in Zone 0...1/Div. 1
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
- Supports plug-in surge protectors
- Very compact, small footprint
- Designed for high reliability
Item Number:
R4D0-FB-IA*
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Outputs | in accordance to FISCO and Entity |
Power dissipation | see table 1 |
Climatic conditions | IEC 60721 |
Degree of protection | IEC/EN 60529 |
Relative humidity | < 95 % non-condensing |
Housing material | Polycarbonate |
Vibration resistance | 1 g , 10 ... 150 Hz |
Connection type | pluggable , screw terminal or spring terminal |
Core cross-section | see table 2 |
Output/Output | No Isolation |
Physical Layer Diagnostic | Signal level at spurs Signal jitter at spurs Noise level at spurs |
Electromagnetic compatibility | NE 21:2011 |
Mass | 2100 g |
Dimensions | see dimensions |
IECEx approval | IECEx BVS 13.0119X |
Ambient temperature | -40 ... 70 В°C (-40 ... 158 В°F) |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Shock resistance | EN 60068-2-27 |
CSA approval | CSA 14.70004139 |
Shock resistance | 15 g 11 ms |
Degree of protection | IP20 , IP30 for Ex-e terminal cover |
LED PWR | green: Fieldbus voltage > 16 V |
Mounting | DIN rail mounting and panel mounting |
Surge protection | Trunk overvoltage protection if voltage exceeds typ. 39 V, max. 41 V |
EU-Type Examination Certificate | BVS 13 ATEX E 121 X |
Marine approval | DNV A-14038 |
Design / Mounting | Cabinet installation |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
FOUNDATION Fieldbus | FF-846 |
Fault Isolation | Short Circuit Current Limitation at spurs Bounce Protection at spurs Signal inhibit at spurs |
Fieldbus standard | IEC 61158-2 |
Main wire/outputs | isolation is not affected by interference according to EN 60079-11, voltage peak value 375 V |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Switch | S1 ON: diagnostic alarms activated S2 ON: diagnostic warnings activated S3-S8: not used |
Vibration resistance | EN 60068-2-6 |
LED COM/ERR | yellow flashing: fieldbus communication and physical layer status , red: Hardware error |
LED SPURS | red: 2 Hz flashing in short-circuit condition |