Pepperl+Fuchs R8D0-MIO-Ex12.FF*
Multi-Input/Output Device for Cabinet Installation

Pepperl+Fuchs R8D0-MIO-Ex12.FF*
We ship to United States of America!
  • For discrete inputs and outputs
  • Installation in Zone 1/Div. 1, intrinsically safe
  • Sensors in Zone 0/Div. 1
  • Connection to fieldbus acc. to FISCO or Entity
  • For FOUNDATION Fieldbus H1
  • PCS integration via device description and function blocks
  • Monitors sensor condition
  • Removable terminals
  • Power, Com, Diagnostics, and Error LEDs
  • Test points for easy troubleshooting
Item Number: R8D0-MIO-Ex12.FF*
1744.71
-
+
Total price: 1744.71
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
ITK version6.1.1
Number of outputs4
Input typeSensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed
Line fault detectionlead breakage , short circuit
Electromagnetic compatibilityNE 21:2011
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Line fault detectionlead breakage , short circuit (not in counter mode)
Degree of protectionIP20
Supply current5 mA
Relative humidity 95 % non-condensing
Switching frequencymin. 0.1 Hz max. 5 kHz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Implementationresource block 1x RS
function block 4x DO, 12x DI, 1x AI, 2x MDI, 1x MDO
transducer block 4x TB
Supply voltage6.6 V
Fieldbus standardIEC 61158-2
Pollution degree2
Supply current1.5 mA
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Rated currentmax. 23 mA
Vibration resistance5 g , 10 ... 150 Hz
Input typeFrequency input / Counter Input , channel 1
Mountingmounting on DIN rail in cabinet
Galvanic isolationEN 60079-11
Input typeSensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable
Number of inputs12
Shock resistance15 g , 11 ms
LED CHANNEL ERRORred, flashing: lead breakage/short circuit; off: no error
Supply voltage5 V
Polaritynot polarity sensitive
Vibration resistanceEN 60068-2-6
FDE (Fault Disconnect Equipment)6.7 mA
Fieldbus typeFOUNDATION Fieldbus
LED PWRgreen: on, bus voltage existent
Number of inputs1
Degree of protectionIEC/EN 60529
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Output typeLow power valve , channels 1, 4, 7, 10
IECEx approvalIECEx BVS 16.0051X
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
EU-Type Examination CertificateBVS 16 ATEX E 075 X
Marine approvalpending
DIP switchAddress setting , write protection , simulation
Pulse durationmin. 80 micro/s
Design / MountingCabinet installation
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
Housing materialPolycarbonate
Ambient temperature-50 ... 75 В°C (-58 ... 167 В°F) hazardous area
-50 ... 85 В°C (-58 ... 185 В°F) safe area
Massapprox. 290 g
Rated voltage9 ... 32 V
Connection typeplug-in terminals , spring terminal and screw terminal
Shock resistanceEN 60068-2-27

Buy Pepperl+Fuchs R8D0-MIO-Ex12.FF* with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services and exceptional support.

Comments

No comments yet

Write a comment