Pepperl+Fuchs R8D0-MIO-Ex12.FF*
Multi-Input/Output Device for Cabinet Installation
We ship to United States of America!
- For discrete inputs and outputs
- Installation in Zone 1/Div. 1, intrinsically safe
- Sensors in Zone 0/Div. 1
- Connection to fieldbus acc. to FISCO or Entity
- For FOUNDATION Fieldbus H1
- PCS integration via device description and function blocks
- Monitors sensor condition
- Removable terminals
- Power, Com, Diagnostics, and Error LEDs
- Test points for easy troubleshooting
Item Number:
R8D0-MIO-Ex12.FF*
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
ITK version | 6.1.1 |
Number of outputs | 4 |
Input type | Sensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed |
Line fault detection | lead breakage , short circuit |
Electromagnetic compatibility | NE 21:2011 |
Foundation Fieldbus/Field circuit | safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V |
Line fault detection | lead breakage , short circuit (not in counter mode) |
Degree of protection | IP20 |
Supply current | 5 mA |
Relative humidity | 95 % non-condensing |
Switching frequency | min. 0.1 Hz max. 5 kHz |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Implementation | resource block 1x RS function block 4x DO, 12x DI, 1x AI, 2x MDI, 1x MDO transducer block 4x TB |
Supply voltage | 6.6 V |
Fieldbus standard | IEC 61158-2 |
Pollution degree | 2 |
Supply current | 1.5 mA |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Rated current | max. 23 mA |
Vibration resistance | 5 g , 10 ... 150 Hz |
Input type | Frequency input / Counter Input , channel 1 |
Mounting | mounting on DIN rail in cabinet |
Galvanic isolation | EN 60079-11 |
Input type | Sensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable |
Number of inputs | 12 |
Shock resistance | 15 g , 11 ms |
LED CHANNEL ERROR | red, flashing: lead breakage/short circuit; off: no error |
Supply voltage | 5 V |
Polarity | not polarity sensitive |
Vibration resistance | EN 60068-2-6 |
FDE (Fault Disconnect Equipment) | 6.7 mA |
Fieldbus type | FOUNDATION Fieldbus |
LED PWR | green: on, bus voltage existent |
Number of inputs | 1 |
Degree of protection | IEC/EN 60529 |
Storage temperature | -40 ... 85 ?°C (-40 ... 185 ?°F) |
Output type | Low power valve , channels 1, 4, 7, 10 |
IECEx approval | IECEx BVS 16.0051X |
LED COM ERR | red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error |
EU-Type Examination Certificate | BVS 16 ATEX E 075 X |
Marine approval | pending |
DIP switch | Address setting , write protection , simulation |
Pulse duration | min. 80 micro/s |
Design / Mounting | Cabinet installation |
Physical layer profile | profile type 511 (FISCO), profile type 111 (Entity) |
Housing material | Polycarbonate |
Ambient temperature | -50 ... 75 ?°C (-58 ... 167 ?°F) hazardous area -50 ... 85 ?°C (-58 ... 185 ?°F) safe area |
Mass | approx. 290 g |
Rated voltage | 9 ... 32 V |
Connection type | plug-in terminals , spring terminal and screw terminal |
Shock resistance | EN 60068-2-27 |
Buy Pepperl+Fuchs R8D0-MIO-Ex12.FF* with the best possible price and delivery terms on eltra-trade.com
Eltra Trade s.r.o. is a trusted online electrical distributor. Our catalog includes a comprehensive range of automation products from leading brands. We offer worldwide delivery and competitive pricing. Streamline your supply chain with our reliable services and exceptional support.
People also buy
Comments
No comments yet