Pepperl+Fuchs R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation

Pepperl+Fuchs R8D0-MIO-Ex12.PA*
  • For discrete inputs and outputs
  • Installation in Zone 1/Div. 1, intrinsically safe
  • Sensors in Zone 0/Div. 1
  • Connection to fieldbus acc. to FISCO or Entity
  • For PROFIBUS PA
  • DCS integration via GSD and FDT/DTM
  • Monitors sensor condition
  • Removable terminals
  • Power, Com, Diagnostics, and Error LEDs
  • Test points for easy troubleshooting
Item Number: R8D0-MIO-Ex12.PA*
1744.71
-
+
Total price: 1744.71
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Supply voltage6.6 V
Degree of protectionIP20
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
IECEx approvalIECEx BVS 16.0051X
Number of outputs4
Input typeFrequency input / Counter Input , channel 1
EU-Type Examination CertificateBVS 16 ATEX E 075 X
Supply voltage5 V
Number of inputs1
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
LED CHANNEL ERRORred, flashing: lead breakage/short circuit; off: no error
Galvanic isolationEN 60079-11
Mountingmounting on DIN rail in cabinet
Electromagnetic compatibilityNE 21:2011
Vibration resistance5 g , 10 ... 150 Hz
DIP switchAddress setting , write protection , simulation
Rated voltage9 ... 32 V
Degree of protectionIEC/EN 60529
Switching frequencymin. 0.1 Hz max. 5 kHz
Polaritynot polarity sensitive
Fieldbus standardIEC 61158-2
Relative humidity 95 % non-condensing
Fieldbus typePROFIBUS PA
Number of inputs12
LED PWRgreen: on, bus voltage existent
Connection typeplug-in terminals , spring terminal and screw terminal
Ambient temperature-50 ... 75 В°C (-58 ... 167 В°F) hazardous area
-50 ... 85 В°C (-58 ... 185 В°F) safe area
Pollution degree2
Vibration resistanceEN 60068-2-6
Supply current5 mA
Supply current1.5 mA
Marine approvalpending
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Massapprox. 290 g
Line fault detectionlead breakage , short circuit (not in counter mode)
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Line fault detectionlead breakage , short circuit
Output typeLow power valve , channels 1, 4, 7, 10
Input typeSensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable
Design / MountingCabinet installation
FDE (Fault Disconnect Equipment)6.7 mA
Input typeSensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed
Shock resistanceEN 60068-2-27
Housing materialPolycarbonate
Pulse durationmin. 80 micro/s
Rated currentmax. 23 mA
Shock resistance15 g , 11 ms