Pepperl+Fuchs R8D0-MIO-Ex12.PA*
Multi-Input/Output Device for Cabinet Installation

Pepperl+Fuchs R8D0-MIO-Ex12.PA*
We ship to United States of America
Item Number: R8D0-MIO-Ex12.PA*
1387.10
-
+
Total price: 1387.10
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Weight, kg: 0,710
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +

Pepperl+Fuchs R8D0-MIO-Ex12.PA*

The R8D0-MIO-Ex12.PA is an intrinsically safe remote I/O module designed for PROFIBUS PA networks. It enables safe and reliable connection of process field devices installed in hazardous areas to modern automation systems.

This module is optimized for process industries where PROFIBUS PA is the preferred communication standard for intelligent field instrumentation.


Key Features

  • Communication protocol: PROFIBUS PA
  • Intrinsically safe I/O for hazardous environments
  • Certified ATEX and IECEx
  • Supports smart transmitters and actuators
  • Continuous line and device diagnostics
  • Modular expandable system design
  • Reduced cabling and commissioning time

Typical Applications

  • Chemical and petrochemical plants
  • Oil & gas production
  • Water treatment facilities
  • Power generation plants
  • Food and pharmaceutical processing
  • The R8D0-MIO-Ex12.PA allows direct PROFIBUS PA communication with field instruments installed in explosive atmospheres.

Technical Characteristics

  • Communication: PROFIBUS PA
  • Protection: Intrinsically safe circuits
  • Hazardous area certification: ATEX / IECEx
  • Integration: Compatible with DCS and PLC systems
  • Diagnostics: Integrated network and device monitoring
  • Mechanical design: Modular rack-based system

Advantages for Your Project

  • Safe operation in hazardous zones
  • Easy integration into existing PROFIBUS PA networks
  • Lower installation costs compared to conventional wiring
  • High system availability through real-time diagnostics

FAQ

Q: What is the difference between PA and FF versions?
A: The PA version communicates via PROFIBUS PA, while the FF version uses Foundation Fieldbus H1.

Q: Can multiple modules be connected on one PA segment?
A: Yes, multiple devices can operate on the same PROFIBUS PA segment according to network design rules.

Q: Is the module certified for hazardous zones?
A: Yes, it is certified for ATEX and IECEx Zone 1 and Zone 2.

Q: Can I get wiring and integration manuals?
A: Yes, full documentation is available on request.


Supply voltage6.6 V

Degree of protectionIP20
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
IECEx approvalIECEx BVS 16.0051X
Number of outputs4
Input typeFrequency input / Counter Input , channel 1
EU-Type Examination CertificateBVS 16 ATEX E 075 X
Supply voltage5 V
Number of inputs1
Storage temperature-40 ... 85 ?°C (-40 ... 185 ?°F)
LED CHANNEL ERRORred, flashing: lead breakage/short circuit; off: no error
Galvanic isolationEN 60079-11
Mountingmounting on DIN rail in cabinet
Electromagnetic compatibilityNE 21:2011
Vibration resistance5 g , 10 ... 150 Hz
DIP switchAddress setting , write protection , simulation
Rated voltage9 ... 32 V
Degree of protectionIEC/EN 60529
Switching frequencymin. 0.1 Hz max. 5 kHz
Polaritynot polarity sensitive
Fieldbus standardIEC 61158-2
Relative humidity95 % non-condensing
Fieldbus typePROFIBUS PA
Number of inputs12
LED PWRgreen: on, bus voltage existent
Connection typeplug-in terminals , spring terminal and screw terminal
Ambient temperature-50 ... 75 ?°C (-58 ... 167 ?°F) hazardous area
-50 ... 85 ?°C (-58 ... 185 ?°F) safe area
Pollution degree2
Vibration resistanceEN 60068-2-6
Supply current5 mA
Supply current1.5 mA
Marine approvalpending
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Massapprox. 290 g
Line fault detectionlead breakage , short circuit (not in counter mode)
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Line fault detectionlead breakage , short circuit
Output typeLow power valve , channels 1, 4, 7, 10
Input typeSensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable
Design / MountingCabinet installation
FDE (Fault Disconnect Equipment)6.7 mA
Input typeSensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed
Shock resistanceEN 60068-2-27
Housing materialPolycarbonate
Pulse durationmin. 80 micro/s
Rated currentmax. 23 mA
Shock resistance15 g , 11 ms

Buy Pepperl+Fuchs R8D0-MIO-Ex12.PA* with the best possible price and delivery terms on eltra-trade.com