Pepperl+Fuchs RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation
- For 8 temperature or analog sensors
- Installation in Zone 1/Div. 1, intrinsically safe
- Sensors in Zone 0/Div. 1
- Connection to fieldbus acc. to FISCO or Entity
- For FOUNDATION Fieldbus H1
- PCS integration via device description and function blocks
- Concentrator method for simplified configuration
- Monitors sensor condition
- For T/C, RTD 2-, 3-, 4-wire, voltage and resistance
- Cold junction compensation
- Removable terminals
Item Number:
RD0-TI-Ex8.FF.*
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Connection type | plug-in terminals , spring terminal and screw terminal |
Vibration resistance | 5 g , 10 ... 150 Hz |
Fieldbus/inputs | safe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V |
Mass | 360 g |
Sensor types | see table 1 |
Fieldbus standard | IEC 61158-2 |
EU-Type Examination Certificate | PTB 03 ATEX 2237 |
Firmware update | via separate plug connection |
Inputs | see EC-Type Examination Certificate |
Physical layer profile | profile type 511 (FISCO), profile type 111 (Entity) |
Certificate | PTB 03 ATEX 2238 X |
Internal measurement cycle | for all sensor types max. 1 s |
Grounding | grounding of thermoelements possible |
Vibration resistance | EN 60068-2-6 |
Degree of protection | IP20 |
Rated current | max. 23 mA |
LED CHANNEL ERROR | red: 2 Hz flashing: lead breakage, overrange; off: no error |
Rated voltage | 9 ... 32 V |
Bus | FISCO see EC-Type Examination Certificate |
Electromagnetic compatibility | NE 21:2011 |
Galvanic isolation | EN 60079-11 |
LED PWR | green: on, bus voltage existent |
IECEx approval | IECEx PTB 05.0001 , IECEx PTB 05.0002X |
Ambient temperature | -40 ... 70 В°C (-40 ... 158 В°F) hazardous area -40 ... 85 В°C (-40 ... 185 В°F) safe area |
Number | 8 |
Macro cycle | typical for one device 8xAI or 1xMAI max. 500 ms |
Common mode voltage | Input to Input 600 Vpeak |
Design / Mounting | Cabinet installation |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Relative humidity | 95 % non-condensing |
LED COM ERR | red, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error |
Degree of protection | IEC 60529 |
Execution time | AI, MAI 40 ms max. |
Implementation | resource block function block transducer block |
Fieldbus type | FOUNDATION Fieldbus |
Housing material | Polycarbonate |
FDE (Fault Disconnect Equipment) | 6.7 mA |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Mounting | mounting on DIN rail in cabinet |
Marine approval | DNV A-14038 |
ITK version | 6.2.0 (DEV_REV 02) |
Shock resistance | 15 g , 11 ms |
Error detection | lead breakage, wiring error, hardware device error |
Polarity | not polarity sensitive |
Shock resistance | EN 60068-2-27 |
People also buy
Comments
No comments yet