Pepperl+Fuchs RD0-TI-Ex8.FF.*
Temperature Multi-Input Device for Cabinet Installation

Pepperl+Fuchs RD0-TI-Ex8.FF.*
  • For 8 temperature or analog sensors
  • Installation in Zone 1/Div. 1, intrinsically safe
  • Sensors in Zone 0/Div. 1
  • Connection to fieldbus acc. to FISCO or Entity
  • For FOUNDATION Fieldbus H1
  • PCS integration via device description and function blocks
  • Concentrator method for simplified configuration
  • Monitors sensor condition
  • For T/C, RTD 2-, 3-, 4-wire, voltage and resistance
  • Cold junction compensation
  • Removable terminals
Item Number: RD0-TI-Ex8.FF.*
4503.89
-
+
Total price: 4503.89
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Connection typeplug-in terminals , spring terminal and screw terminal
Vibration resistance5 g , 10 ... 150 Hz
Fieldbus/inputssafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Mass360 g
Sensor typessee table 1
Fieldbus standardIEC 61158-2
EU-Type Examination CertificatePTB 03 ATEX 2237
Firmware updatevia separate plug connection
Inputssee EC-Type Examination Certificate
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
CertificatePTB 03 ATEX 2238 X
Internal measurement cyclefor all sensor types max. 1 s
Groundinggrounding of thermoelements possible
Vibration resistanceEN 60068-2-6
Degree of protectionIP20
Rated currentmax. 23 mA
LED CHANNEL ERRORred: 2 Hz flashing: lead breakage, overrange; off: no error
Rated voltage9 ... 32 V
BusFISCO see EC-Type Examination Certificate
Electromagnetic compatibilityNE 21:2011
Galvanic isolationEN 60079-11
LED PWRgreen: on, bus voltage existent
IECEx approvalIECEx PTB 05.0001 , IECEx PTB 05.0002X
Ambient temperature-40 ... 70 В°C (-40 ... 158 В°F) hazardous area
-40 ... 85 В°C (-40 ... 185 В°F) safe area
Number8
Macro cycletypical for one device 8xAI or 1xMAI max. 500 ms
Common mode voltageInput to Input 600 Vpeak
Design / MountingCabinet installation
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Relative humidity 95 % non-condensing
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
Degree of protectionIEC 60529
Execution timeAI, MAI 40 ms max.
Implementationresource block1x RS
function block8x AI, 1x MAI
transducer block8x sensor TB, 1x concentrator TB
Fieldbus typeFOUNDATION Fieldbus
Housing materialPolycarbonate
FDE (Fault Disconnect Equipment)6.7 mA
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Mountingmounting on DIN rail in cabinet
Marine approvalDNV A-14038
ITK version6.2.0 (DEV_REV 02)
Shock resistance15 g , 11 ms
Error detectionlead breakage, wiring error, hardware device error
Polaritynot polarity sensitive
Shock resistanceEN 60068-2-27

Comments

No comments yet

Write a comment