Pepperl+Fuchs RLK28-55/31/116
Retroreflective sensor
- Universal series with highly versatile fields of use
- Resistant against noise: reliable operation under all conditions
- Version with red light
- Version with relay output
- Overview
- Comments
Connection | terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland |
UL approval | E87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. |
Diameter of the light spot | approx. 290 mm at a distance of 17 m |
Product standard | EN 60947-5-2 |
Housing height | 88 mm |
Housing depth | 65.5 mm |
Function indicator | 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted |
Effective detection range | 0 ... 17 m |
Degree of protection | IP67 |
Switching power | DC: max. 50 W AC: max. 500 VA |
Mass | 112 g |
Signal output | Relay, 1 alternator |
Reference target | H85-2 reflector |
Switching type | light/dark on switchable |
Switching voltage | max. 250 V AC/DC |
Threshold detection range | 21 m |
Storage temperature | -40 ... 75 В°C (-40 ... 167 В°F) |
Switching current | max. 2 A |
Response time | 20 ms |
Housing width | 25.8 mm |
Light source | LED |
Control elements | sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch |
Mission Time (TM) | 20 a |
Operation indicator | LED green |
Switching frequency | 25 Hz |
Polarization filter | yes |
Diagnostic Coverage (DC) | 0 % |
Ambient temperature | -40 ... 60 В°C (-40 ... 140 В°F) |
Angle of divergence | emitter 1.2В° receiver 2В° |
Operating voltage | 12 ... 240 V AC/DC |
Protection class | II, rated insulation voltage 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. |
CCC approval | Certified by China Compulsory Certification (CCC) |
EAC conformity | TR CU 020/2011 TR CU 004/2011 |
MTTFd | 600 a |
Light type | modulated visible red light |
Power consumption | 3.5 VA |
Ambient light limit | 80000 Lux |
Reflector distance | 0.05 ... 17 m |
People also buy
Comments
No comments yet