Pepperl+Fuchs RLK28-55-Z/31/116
Retroreflective sensor

Pepperl+Fuchs RLK28-55-Z/31/116
  • Universal series with highly versatile fields of use
  • Resistant against noise: reliable operation under all conditions
  • Programmable time function GAN, GAB, IAB, as well as GAN-GAB and GAN-IAB as double function
  • Version with red light
  • Version with relay output
Item Number: RLK28-55-Z/31/116
311.63
-
+
Total price: 311.63
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Operating voltage12 ... 240 V AC/DC
Housing depth65.5 mm
Power consumption 3.5 VA
Light typemodulated visible red light
Ambient light limit80000 Lux
Control elementssensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch
Housing width25.8 mm
Mission Time (TM)20 a
Connectionterminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland
Threshold detection range21 m
Switching powerDC: max. 50 W AC: max. 500 VA
Light sourceLED
Effective detection range0 ... 17 m
Polarization filteryes
Switching typelight/dark on switchable
Housing height88 mm
Function indicator2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted
Protection classII, rated insulation voltage 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140.
Caution!
The protection class 2 is only valid when the terminal compartment is closed.
Diagnostic Coverage (DC)0 %
EAC conformityTR CU 020/2011
TR CU 004/2011
Diameter of the light spotapprox. 290 mm at a distance of 17 m
UL approvalE87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508.
Operation indicatorLED green
Degree of protectionIP67
Storage temperature-40 ... 75 В°C (-40 ... 167 В°F)
Signal outputRelay, 1 alternator
MTTFd600 a
Switching frequency25 Hz
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F)
Switching currentmax. 2 A
Angle of divergenceemitter 1.2В°
receiver 2В°
Timer functionON delay (GAN), OFF delay (GAB), one shot (IAB), ON delay-one shot (GAN-IAB), ON delay-OFF delay (GAN-GAB), programmable
adjustment interval 0.1 ... 10 s
Product standardEN 60947-5-2
CCC approvalCertified by China Compulsory Certification (CCC)
Switching voltagemax. 250 V AC/DC
Reflector distance0.05 ... 17 m
Mass112 g
Reference targetH85-2 reflector
Response time20 ms

Comments

No comments yet