Pepperl+Fuchs SB4-OR-4CP-4M
Safety control unit
- Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off)
- 4 sensor channels
- Self-monitoring (type 4 according to IEC/EN 61496-1)
- Operating mode can be selected by means of DIP switches
- Start/Restart disable
- Relay monitor
- Sequential and parallel muting in various operating modes
- Double muting
- Emergency muting for the correction of the material jam
- Pre-fault indication
- Clearly visible LED functional display
- 7-segment diagnostic display
- Safety outputs OSSD, external status displays OSSD
Item Number:
SB4-OR-4CP-4M
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Operating voltage | 24 V DC, В± 20 % |
Function indicator | LED red: OSSD OFF LED green: OSSD ON Yellow LED: start readiness channel 1 - 4 LED yellow: switching state (receiver) |
Signal output | 1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off, muting lamp |
Diagnostics indicator | 7-segment display |
Performance level (PL) | PL e |
Operating mode | Start/restart disable, relay monitor, muting operating modes |
Mission Time (TM) | 20 a |
Connection | screw terminals , lead cross section 0.2 ... 2 mm2 |
Functional safety | ISO 13849-1 ; EN 61508 part1-4 |
Category | Cat. 4 |
Safety output | 2 relay outputs, force-guided NO-contact |
Product standard | EN 61496-1 |
PFHd | 3.5 E-9 |
Switching current | min. 10 mA , max. 6 A AC/DC |
Pre-fault indicator | LED yellow flashing: Indicator lamp channel 1 ... 4 |
Switching voltage | 10 V ... 250 V AC/DC |
Degree of protection | IP20 |
B10d | see instruction manuals |
Safety Integrity Level (SIL) | SIL 3 |
People also buy