Pepperl+Fuchs SB4-OR-4XP
Safety control unit

Pepperl+Fuchs SB4-OR-4XP
  • Evaluation unit for security through-beam sensors SLA5(S) and SLA40- for safety light grids SLP, for safety light curtains SLC- for switching pads and emergency stop buttons of categories 2 and 4
  • 4 sensor channels
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Operating mode can be selected by means of DIP switches
  • Start/Restart disable
  • Relay monitor
  • Pre-fault indication
  • Clearly visible LED functional display
  • 7-segment diagnostic display
  • Safety outputs OSSD, external status displays OSSD
Item Number: SB4-OR-4XP
795.50
-
+
Total price: 795.50
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Connectionscrew terminals , lead cross section 0.2 ... 2 mm2
Operating voltage24 V DC, В± 20 %
Performance level (PL)PL e
Switching currentmin. 10 mA , max. 6 A AC/DC
Safety Integrity Level (SIL)SIL 3
Product standardEN 61496-1
Function indicatorLED red: OSSD OFF
LED green: OSSD ON
Yellow LED: start readiness channel 1 - 4
LED yellow: switching state (receiver)
Safety output2 relay outputs, force-guided NO-contact
Signal outputOutput for displaying the switching state of the OSSDs
Diagnostics indicator7-segment display
Functional safetyISO 13849-1 ; EN 61508 part1-4
B10dsee instruction manuals
Degree of protectionIP20
Mission Time (TM)20 a
PFHd3.5 E-9
Switching voltage10 V ... 250 V AC/DC
CategoryCat. 4
Pre-fault indicatorLED yellow flashing: Indicator lamp channel 1 ... 4
Operating modeStart/restart disable, relay monitor,

Comments

No comments yet

Write a comment