Pepperl+Fuchs SC3,5-N0-Y106571 Inductive slot sensor


Item Number: SC3,5-N0-Y106571
- Comfort series
- 3.5 mm slot width
- Overview
- Datasheet
- Alternative numbers
- Comments
Type of protection | intrinsic safety |
Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
MTTFd | 5290 a |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 72 В°C (161.6 В°F) T5 : 87 В°C (188.6 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 65 В°C (149 В°F) T5 : 80 В°C (176 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 40 В°C (104 В°F) T5 : 55 В°C (131 В°F) T4 : 75 В°C (167 В°F) T3 : 75 В°C (167 В°F) T2 : 75 В°C (167 В°F) T1 : 75 В°C (167 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 23 В°C (73.4 В°F) T5 : 38 В°C (100.4 В°F) T4 : 54 В°C (129.2 В°F) T3 : 54 В°C (129.2 В°F) T2 : 54 В°C (129.2 В°F) T1 : 54 В°C (129.2 В°F) |
CE marking | [*PD-Z02585A*] |
Output type | 2-wire |
Switching frequency | 0 ... 3000 Hz |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 75 В°C (167 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 54 В°C (129.2 В°F) |
Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
Type of protection | intrinsic safety |
Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
Output type | NAMUR |
Core cross-section | 0.14 mm2 |
Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
Nominal voltage | 8 V |
Equipment protection level | Ga , Gb , Da , Mb |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Diagnostic Coverage (DC) | 0 % |
UL approval | cULus Listed, General Purpose |
Switching function | Normally closed (NC) |
Use in the hazardous area | see instruction manuals |
Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
Operating voltage | 5 ... 25 V |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
Effective internal inductance | max. 150 µH A cable length of 10 m is considered. |
Type of protection | intrinsic safety |
Hysteresis | 0 ... 0.05 |
Slot width | 3.5 mm |
CE marking | [*PD-Z02585A*] |
Housing material | PBT |
Degree of protection | IP67 (plug connector, IP20) |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 75 В°C (167 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 54 В°C (129.2 В°F) |
Mission Time (TM) | 20 a |
Type of protection | intrinsic safety |
Connection type | 65 mm PVC cord with DuPont connector |
CSA approval | cCSAus Listed, General Purpose |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. |
Effective internal capacitance | max. 150 nF A cable length of 10 m is considered. |
People also buy
Comments
No comments yet