Type of protection | intrinsic safety |
Output type | 2-wire |
CE marking | [*PD-Z02586A*] |
Housing material | PBT |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
Switching function | Normally closed (NC) |
Output type | NAMUR with safety function |
Switching frequency | 0 ... 3000 Hz |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 В°C (192.2 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 В°C (165.2 В°F) |
Diagnostic Coverage (DC) | 0 % |
Effective internal inductance | max. 100 µH A cable length of 10 m is considered. |
CE marking | [*PD-Z02585A*] |
Type of protection | intrinsic safety |
Degree of protection | IP67 |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 70 В°C (158 В°F) T5 : 85 В°C (185 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 В°C (150.8 В°F) T5 : 81 В°C (177.8 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 В°C (113 В°F) T5 : 60 В°C (140 В°F) T4 : 89 В°C (192.2 В°F) T3 : 89 В°C (192.2 В°F) T2 : 89 В°C (192.2 В°F) T1 : 89 В°C (192.2 В°F) at Ui = 20 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 В°C (86 В°F) T5 : 45 В°C (113 В°F) T4 : 74 В°C (165.2 В°F) T3 : 74 В°C (165.2 В°F) T2 : 74 В°C (165.2 В°F) T1 : 74 В°C (165.2 В°F) |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 89 В°C (192.2 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 74 В°C (165.2 В°F) |
CE marking | [*PD-Z02585A*] |
Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the ""exida Functional Safety Assessment"" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
Type of protection | intrinsic safety |
Reference target | 10 x 7 x 0.3 mm3, Al |
Safety Integrity Level (SIL) | SIL 3 |
Type of protection | intrinsic safety |
Connection type | flexible leads LiY , 150 mm |
Mission Time (TM) | 20 a |
Use in the hazardous area | see instruction manuals |
UL approval | cULus Listed, General Purpose |
Effective internal inductance | max. 100 µH A cable length of 10 m is considered. |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 В°C (163.4 В°F) T5 : 88 В°C (190.4 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 66 В°C (150.8 В°F) T5 : 81 В°C (177.8 В°F) T4 : 100 В°C (212 В°F) T3 : 100 В°C (212 В°F) T2 : 100 В°C (212 В°F) T1 : 100 В°C (212 В°F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 В°C (113 В°F) T5 : 60 В°C (140 В°F) T4 : 89 В°C (192.2 В°F) T3 : 89 В°C (192.2 В°F) T2 : 89 В°C (192.2 В°F) T1 : 89 В°C (192.2 В°F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 В°C (86 В°F) T5 : 45 В°C (113 В°F) T4 : 74 В°C (165.2 В°F) T3 : 74 В°C (165.2 В°F) T2 : 74 В°C (165.2 В°F) T1 : 74 В°C (165.2 В°F) |
Ambient temperature | -40 ... 100 В°C (-40 ... 212 В°F) |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
EMC in accordance with | EN 60947-5-2:2007 + A1:2012 IEC 60947-5-2:2007 + A1:2012 |
MTTFd | 11800 a |
Hysteresis | with NAMUR switch amplifier: 0.045 mm (e. g. Pepperl+Fuchs KCD2-SR-Ex1.LB) with safety switch amplifier 0.025 mm (e. g. Pepperl+Fuchs KFD2-SH-Ex1) |
Core cross-section | 0.14 mm2 |
Nominal voltage | 8.2 V |
Effective internal inductance | max. 100 µH A cable length of 10 m is considered. |
Rate of current rise | -4.5 mA / mm |
Effective internal inductance | max. 100 µH A cable length of 10 m is considered. |
Equipment protection level | Gb , Gc (ic) , Da , Mb |
Slot width | 3.5 mm |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. |
Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |