Pepperl+Fuchs SLC-2/31
Safety light grid with integrated control unit
- Sensing range up to 20 m
- 2, 3, and 4-beam design
- Beam distance 300, 400 and 500 mm
- Self-monitoring (type 4 according to IEC/EN 61496-1)
- Start/Restart disable
- Degree of protection IP67
- 7-segment diagnostic display
- Pre-fault indication
- Safety outputs OSSD in potential-separated semiconductor design or with monitored, compelled connection NC-contacts
- Optional with relay monitor (Option 129)
- Overview
- Comments
Mission Time (TM) | 20 a |
Mass | Per 2100 g |
TГњV approval | TГњV |
Signal output | 1 PNP each, max. 100 mA for start readiness and OSSD status |
CE conformity | CE |
Connection options | Further electrical connection options on request: Connector M12, 8-pin Connector DIN 43 651 Hirschmann, 6-pin+PE Connector M26x11 Hirschmann, 11-pin+PE |
Light source | IRED |
Operating voltage | 24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %) |
Ambient temperature | 0 ... 55 В°C (32 ... 131 В°F) |
Switching current | max. 2 A |
Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready |
Beam spacing | 500 mm |
Activation time | 0.03 ... 1 s |
Functional safety | ISO 13849-1 |
Control elements | switch for start/restart disable, transmission coding |
Safety type according to IEC/EN 61496 | 4 |
Degree of protection | IP67 |
Receiver | SLC-2-R/31 |
Emitter | SLC-2-T |
Tests | IEC/EN 61496 |
Response time | 30 ms |
Function input | Start release |
UL approval | cULus Listed |
Pre-fault indicator | LED orange |
Safety output | 2 relay outputs, force-guided NO-contact |
Number of beams | 2 |
Operating mode | can be selected with or without start/restart disable |
LED risk group labelling | exempt group |
Diagnostics indicator | 7-segment display in receiver |
Angle of divergence | < 5 В° |
Switching voltage | 50 V |
PFHd | 7.27 E-9 |
Type | 4 |
Relative humidity | max. 95 %, not condensing |
Performance level (PL) | PL e |
Effective detection range | 0.2 ... 20 m |
Safety Integrity Level (SIL) | SIL 3 |
Operation indicator | 7-segment display in emitter |
Activation current | approx. 10 mA |
Protection class | III |
Switching power | 100 VA |
Test input | Reset-input for system test |
Storage temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Category | Cat. 4 |
Product standard | EN 61496-1 ; IEC 61496-2 |
No-load supply current | Emitter: 100 mA , receiver 150 mA |
Target size | 50 mm |
CCC approval | CCC approval / marking not required for products rated 36 V |
Light type | modulated infrared light |
Connection | M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 |