Pepperl+Fuchs SLC-2/31
Safety light grid with integrated control unit

Pepperl+Fuchs SLC-2/31
  • Sensing range up to 20 m
  • 2, 3, and 4-beam design
  • Beam distance 300, 400 and 500 mm
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Start/Restart disable
  • Degree of protection IP67
  • 7-segment diagnostic display
  • Pre-fault indication
  • Safety outputs OSSD in potential-separated semiconductor design or with monitored, compelled connection NC-contacts
  • Optional with relay monitor (Option 129)
Item Number: SLC-2/31
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Mission Time (TM)20 a
MassPer 2100 g
TГњV approvalTГњV
Signal output1 PNP each, max. 100 mA for start readiness and OSSD status
CE conformityCE
Connection optionsFurther electrical connection options on request:
Connector M12, 8-pin
Connector DIN 43 651 Hirschmann, 6-pin+PE
Connector M26x11 Hirschmann, 11-pin+PE
Light sourceIRED
Operating voltage24 V DC (-30 %/+25 %) / 24 V AC (-20 %/+10 %)
Ambient temperature0 ... 55 В°C (32 ... 131 В°F)
Switching currentmax. 2 A
Function indicatorin receiver:
LED red: OSSD off
LED green: OSSD on
LED yellow: Protected area free, system start-ready
Beam spacing500 mm
Activation time0.03 ... 1 s
Functional safetyISO 13849-1
Control elementsswitch for start/restart disable, transmission coding
Safety type according to IEC/EN 614964
Degree of protectionIP67
ReceiverSLC-2-R/31
EmitterSLC-2-T
TestsIEC/EN 61496
Response time30 ms
Function inputStart release
UL approvalcULus Listed
Pre-fault indicatorLED orange
Safety output2 relay outputs, force-guided NO-contact
Number of beams2
Operating modecan be selected with or without start/restart disable
LED risk group labellingexempt group
Diagnostics indicator7-segment display in receiver
Angle of divergence< 5 В°
Switching voltage50 V
PFHd7.27 E-9
Type4
Relative humiditymax. 95 %, not condensing
Performance level (PL)PL e
Effective detection range0.2 ... 20 m
Safety Integrity Level (SIL)SIL 3
Operation indicator7-segment display in emitter
Activation currentapprox. 10 mA
Protection classIII
Switching power100 VA
Test inputReset-input for system test
Storage temperature-25 ... 70 В°C (-13 ... 158 В°F)
CategoryCat. 4
Product standardEN 61496-1 ; IEC 61496-2
No-load supply currentEmitter: 100 mA , receiver 150 mA
Target size50 mm
CCC approvalCCC approval / marking not required for products rated 36 V
Light typemodulated infrared light
ConnectionM20 cable gland ,
terminal compartment with screw terminals, lead cross-section max. 1.5 mm2

Comments

No comments yet

Write a comment