Pepperl+Fuchs SLCS30
Safety light curtain
- Resolution 30 mm (hand protection)
- Protection field height up to 2400 mm
- Self-monitoring (type 4 according to IEC/EN 61496-1)
- SIL3 (IEC 61508)
- Degree of protection IP67
- Temperature range -35 ... 60В°C (-31 ... 140 В°F)
- Slim design, mounting on three sides
Item Number:
SLCS30
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Input type | Transmitter unit test |
Function indicator | Green: OSSD ON , Red: OSSD OFF |
Degree of protection | IP67 , For indoor use only |
CE conformity | CE |
PFHd | Depending on the protection field height; see Manual |
Input type | Receiver unit relay monitor |
Connection | Transmitter unit: 4-pin, M12 x 1 connector Receiver: 8-pin, M12 x 1 connector Cable cross section min. 0.25 mm2 Max. cable length 50 m |
Operating mode | Startup/restart disable, deactivateable |
Category | Cat. 4 |
Angle of divergence | < 5 В° |
Effective detection range | 0.4 ... 8 m |
Output type | Receiver unit OSSD |
Operation indicator | green: Power on |
Output type | Receiver signal output start readiness |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Mission Time (TM) | 20 a |
Safety Integrity Level (SIL) | SIL 3 |
TГњV approval | TГњV |
Operating voltage | 24 V DC (-20%, +30%) ; Power supply with safe isolation: 24 V DC |
Response time | see Table 1, max. 38 ms |
Performance level (PL) | PL e |
Functional safety | ISO 13849-1 ; EN 61508 part1-4 |
UL File Number | E215245 |
Ambient temperature | -35 ... 60 В°C (-31 ... 140 В°F) |
Input type | Receiver unit, start release |
Type | 4 |
Protection class | III , IEC 61140 |
Signal output | PNP semiconductor , monitored for short and cross circuits |
Signal output | PNP-semiconductor, short-circuit protected, 0.1A |
CCC approval | CCC approval / marking not required for products rated 36 V |
Input format | Break contact |
UL approval | cULus Listed |
Input format | Break contact |
Status indicator | Transmitter unit: LED yellow: Mode, test or error Receiver: LED yellow: Start readiness, function reserve or error |
Function | Beam Code A: open or 0 V Beam Code B: 24 V DC, 5 mA |
Input current | 5 mA |
Optical resolution | 30 mm |
Input format | Break contact |
Switching voltage | ON: UB - 2 V; OFF: < 1 V |
Input type | Transmitter unit, mode A/B |
Mass | see table 2 |
Housing length L | see table 2 |
Input type | Receiver unit, mode A/B (see transmitter unit, mode A/B) |
No-load supply current | Transmitter unit: 150 mA Receiver: 150 mA (without outputs) |
Light type | modulated infrared light , 850 nm |
Product standard | EN 61496-1 ; IEC 61496-2 |
Input current | 5 mA |
Switching voltage | 24 V DC |
Power consumption | Transmitter unit: 5 W Receiver: 15 W |
Ambient light limit | Not sensitive to ambient light in accordance with IEC 61496-2 |
Light source | IRED |
Storage temperature | -35 ... 70 В°C (-31 ... 158 В°F) |
Input current | 5 mA |
Switching current | ON: max. 0.1 A; OFF: < 5 ВµA |
Relative humidity | max. 95 %, not condensing |
Switching voltage | 24 V DC |
Protection field height | see Table 1, max. 2400 mm |
People also buy
Comments
No comments yet